Abstract
The design and construction of a synchronous-scanning underwater imaging system capable of rapid two-dimensional scanning are described. The imager employs a 7-W, all-lines, argon-ion laser in conjunction with a galvanometrically driven raster scanner and an image-dissector tube receiver. The imager is capable of directly generating real-time RS-170 video imagery. The results of an in-water test of the imaging system, in which a high-contrast imaging test pattern was imaged, demonstrate operating ranges of up to 4 attenuation lengths (AL) when the test was run at real-time frame rates, ranges of 5.1-5.5 AL when the system operated with an eight-frame running average, and ranges of 6.3 AL when a 128-frame running average was used. The system performance was compared with that of several floodlight/silicon-intensified-target TV camera configurations, which produced a maximum imaging range of ∼ 2.6 AL. Also, an imaging configuration that used the raster-scanned beam of the laser as an illumination source for the silicon-intensified-target camera was tested. That system had an ultimate range of ∼ 4 AL.
© 1993 Optical Society of America
Full Article | PDF ArticleMore Like This
Thomas G. McRae and Thomas J. Kulp
Appl. Opt. 32(21) 4037-4050 (1993)
Karl D. Moore
Appl. Opt. 40(33) 5991-6004 (2001)
Thomas J. Kulp, Peter Powers, Randall Kennedy, and Uta-Barbara Goers
Appl. Opt. 37(18) 3912-3922 (1998)