Measurement of Small Volume Flame Temperatures by the Two-line Atomic Fluorescence Method

Not Accessible

Your library or personal account may give you access

Abstract

Measurement of small volume temperatures of analytical flames by the two-line atomic fluorescence technique involving the use of direct-line Stokes and anti-Stokes fluorescence of indium and thallium has been examined. Spatial flame temperatures have been measured with a volume resolution of 0.3 mm by 2 mm by 5 mm in the flame. Theoretical and practical considerations of the method are given, particularly in terms of the limitation of using indium or thallium. The use of the two thallium lines (377.57 and 535.05 nm) was subject to fewer random errors than the use of the two indium lines (410.18 and 451.13 nm) for the range of temperatures studied. However, thallium lines are restricted to the measurement of temperatures above about 2000°K (for the air-acetylene and nitrous oxide-acetylene flames); for temperatures below about 2000°K, the fluorescence irradiance ratio could not be measured with sufficient signal/noise ratio due to the low intensity of the anti-Stokes fluorescence line. In the present experiment, indium lines were used for the measurement of a wide range of "low" flame temperatures (approximately 700 to 2600°K) owing to the better signal/noise ratios for both lines; indium lines were also preferable for the air-acetylene flame, even though the error produced by the random uncertainty in the fluorescence ratio was larger than for thallium. The present method has been successfully applied to the measurement of the spatial temperature profiles of analytical flames. such as argon-hydrogen(-entrained air), argon-oxygen-hydrogen air-acetylene, and nitrous oxide-acetylene.

PDF Article
More Like This
Two-line atomic fluorescence temperature measurement in flames: an experimental study

Richard G. Joklik and John W. Daily
Appl. Opt. 21(22) 4158-4162 (1982)

Spatially resolved temperature measurements in a flame using laser-excited two-line atomic fluorescence and diode-array detection

M. Aldén, P. Grafstrom, H. Lundberg, and S. Svanberg
Opt. Lett. 8(5) 241-243 (1983)

Two-line atomic fluorescence as a temperature probe for highly sooting flames

J. Engström, J. Nygren, M. Aldén, and C. F. Kaminski
Opt. Lett. 25(19) 1469-1471 (2000)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.