Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 34,
  • Issue 6,
  • pp. 652-656
  • (1980)

The Control of Errors in Infrared Spectrophotometry. VI. The Evaluation of Optical Constants by Combined Transmission and Attenuated Total Reflection Measurements

Not Accessible

Your library or personal account may give you access

Abstract

An improved technique is described for the determination of the optical constants of liquids in the infrared. It is based on a combination of transmission and attenuated total reflection (ATR) measurements. A novel application of the Kramers-Kronig transform function is involved whereby a single-valued integration constant is derived from a vector of refractive index measurements obtained by ATR. These are measured over a wavenumber range where the absorbance is low. It has been shown in earlier work that by an appropriate choice of a low refractive index contact material (in our case sodium chloride) the ATR method has high precision and accuracy under these conditions. The accuracy of the method is evaluated on the basis of a statistical treatment of the propagation of the estimated errors in the experimentally measured quantities, viz., the transmittance, the cell thickness, and the ATR measurements which establish the integration constant (anchor point) of the Kramers-Kronig transform function. The transmittance measurements are made at several cell thicknesses. The data reduction computer program, by which the optical constants are evaluated from the transmission measurements, monitors these sets of data and selects at each wavenumber the one having the minimal statistical error.

PDF Article
More Like This
Attenuated total reflection method for obtaining the optical constants of powders

Ian R. Chandler, Vincent P. Tomaselli, and K. D. Moller
Appl. Opt. 22(24) 4099-4104 (1983)

Attenuated-total-reflection technique for the determination of optical constants

L. E. Regalado, R. Machorro, and J. M. Siqueiros
Appl. Opt. 30(22) 3176-3180 (1991)

Optical constants of polyimide films in the soft x-ray region from reflection and transmission measurements

R. Wolf, H.-G. Birken, and C. Kunz
Appl. Opt. 31(34) 7313-7327 (1992)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.