Multichannel FT-Raman Spectroscopy: Noise Analysis and Performance Assessment

Not Accessible

Your library or personal account may give you access

Abstract

A Raman spectrometer based on forming an interferogram on a charge-coupled device (CCD) detector is evaluated further with respect to signal-to-noise ratio (SNR), stability, response correction, and resolution. The multichannel Fourier transform technique differs fundamentally from dispersive spectrometers and FT-Raman systems based on Michelson interferometers. Changes in entrance optics permitted multitrack operation and an improvement in collection efficiency. Both hardware and a more facile software procedure were examined for correction of noise caused by nonuniformity of the CCD response. The instrumental linewidth (ILW) for the multichannel Fourier transform (MCFT) system examined here was 14 cm -1 (full width at half-maximum), close to the 13.5 cm -1 predicted theoretically. An optical heterodyne method was used to downshift the observed Raman features and further reduce the ILW to 8 cm -1. The unheterodyned MCFT spectrometer has a lower SNR than do dispersive systems for most samples, but has the advantages of frequency precision and large throughput. Several applications of MCFT are discussed, including examination of photolabile samples, multiple sample monitoring with fiber optics, and identification of MCFT spectra with a dispersive library.

PDF Article
More Like This
Development of a multichannel Fourier transform spectrometer

Noboru Ebizuka, Moriaki Wakaki, Yukiyasu Kobayashi, and Syuji Sato
Appl. Opt. 34(34) 7899-7906 (1995)

Performance assessment of probe-based Raman spectroscopy systems for biomedical analysis

Sean Fitzgerald, Eric Marple, and Anita Mahadevan-Jansen
Biomed. Opt. Express 14(7) 3597-3609 (2023)

Multichannel Fourier-transform infrared spectrometer

Mamoru Hashimoto and Satoshi Kawata
Appl. Opt. 31(28) 6096-6101 (1992)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.