Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 67,
  • Issue 8,
  • pp. 993-996
  • (2013)

Thermal Stability of Intralipid Optical Phantoms

Not Accessible

Your library or personal account may give you access

Abstract

We investigated the stability of light transmission through Intralipid-based optical phantoms in the wavelength range of 400-950 nm at temperatures between 35 and 70 °C. Optical phantoms are materials commonly used to simulate the light scattering and absorption properties of biological materials. These simulations require the phantom to be optically stable. We demonstrate that the scattering properties of Intralipid remain stable at higher temperatures, varying less than 0.5%. We also present results that show this is not the case for absorption below 700 nm at 35 and 70 °C, with greater instability at 70 °C. For example, at 500 nm, the light intensity transmitted through 15 mm of Intralipid dropped 39% over 12 h. We demonstrate that oxidation of fatty acids in Intralipid could account for this effect and show, by flushing the system continuously with nitrogen gas, the instability is reduced.

PDF Article
More Like This
Effect of dependent scattering on the optical properties of Intralipid tissue phantoms

Paola Di Ninni, Fabrizio Martelli, and Giovanni Zaccanti
Biomed. Opt. Express 2(8) 2265-2278 (2011)

Supercontinuum laser based optical characterization of Intralipid® phantoms in the 500-2250 nm range

Ben Aernouts, Eduardo Zamora-Rojas, Robbe Van Beers, Rodrigo Watté, Ling Wang, Mizuki Tsuta, Jeroen Lammertyn, and Wouter Saeys
Opt. Express 21(26) 32450-32467 (2013)

Determination of reference values for optical properties of liquid phantoms based on Intralipid and India ink

L. Spinelli, M. Botwicz, N. Zolek, M. Kacprzak, D. Milej, P. Sawosz, A. Liebert, U. Weigel, T. Durduran, F. Foschum, A. Kienle, F. Baribeau, S. Leclair, J.-P. Bouchard, I. Noiseux, P. Gallant, O. Mermut, A. Farina, A. Pifferi, A. Torricelli, R. Cubeddu, H.-C. Ho, M. Mazurenka, H. Wabnitz, K. Klauenberg, O. Bodnar, C. Elster, M. Bénazech-Lavoué, Y. Bérubé-Lauzière, F. Lesage, et al.
Biomed. Opt. Express 5(7) 2037-2053 (2014)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved