Abstract
Energy levels for Th i were computed from the weighted averages of wavelengths from seven sets of published interferometrically measured data. The most self-consistent energy levels obtained in this way were then employed to calculate wavenumbers that have a standard deviation of less than 10 mK. We propose that these lines be adopted as class-B secondary standards. Calculated wavelengths of 1375 Th i lines and weighted averages of 181 interferometrically measured Th i and Th ii lines between 2565 and 12 381 Å are given.
© 1970 Optical Society of America
Full Article | PDF ArticleMore Like This
Francisco P. J. Valero
J. Opt. Soc. Am. 60(12) 1675-1680 (1970)
A. Davison, A. Giacchetti, and R. W. Stanley
J. Opt. Soc. Am. 52(4) 447-451 (1962)
Francisco P. J. Valero
J. Opt. Soc. Am. 58(4) 484-489 (1968)