Autofluorescence removal from fluorescence tomography data usingmultispectral imaging

Stylianos Psycharakis, Giannis Zacharakis, Anikitos Garofalakis, Rosy Favicchio, and Jorge Ripoll

http://dx.doi.org/10.1364/ECBO.2007.6626_14


View Full Text Article

Acrobat PDF (885 KB) Note that full-text PDFs from conferences typically contain 1-3 pages of content, some or all of which might be an abstract, summary, or miscellaneous items.





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

Autofluorescence has been a significant disadvantage when dealing with tomographic imaging of biological samples or tissue phantoms. Consequently, the accurate removal of autofluorescence signal has been a major concern in fluorescence tomography. Here we present a study on three-dimensional mapping and removal of autofluorescence from fluorescence molecular tomography (FMT) data, both for phantoms and small animal in vivo. The technique is based on the recording of tomographic data in multiple spectral regions with different excitation light and on the application of a linear unmixing algorithm for targeting multiple fluorescent probes. Two types of measurements are taken, one with the excitation being in the region of the maximum absorption of the targeted fluorophore and one in a region away from the maximum. The relative strengths of the different spectra are employed to calculate the signal to be removed from the tomographic reconstruction. Autofluorescence spectra are recorded using identical reflection geometry as during the FMT acquisitions allowing for the correct mapping of the autofluorescence signal. Results from phantoms exhibiting different background autofluorescence strengths are presented and discussed. In this work we have also studied in vivo fluorescent activity in mice, involving both subcutaneously implanted fluorescent phantoms and b10 transgenic mice.

© 2007 SPIE

Citation
S. Psycharakis, G. Zacharakis, A. Garofalakis, R. Favicchio, and J. Ripoll, "Autofluorescence removal from fluorescence tomography data usingmultispectral imaging," in Molecular Imaging, K. Licha and V. Ntziachristos, eds., Vol. 6626 of Proceedings of SPIE-OSA Biomedical Optics (Optical Society of America, 2007), paper 6626_14.