Abstract
We introduce a fitting procedure which can quantitatively recover the absorption coefficient using DOT-assisted photoacoustic tomography. The background optical properties provided by DOT can significantly improve the accuracy of the fitting.
© 2010 Optical Society of America
PDF ArticleMore Like This
Adam Q. Bauer, Ralph E. Nothdurft, Changhui Li, Lihong V. Wang, and Joseph P. Culver
BTuD24 Biomedical Optics (BIOMED) 2010
Zhen Yuan and Huabei Jiang
SH71 Biomedical Topical Meeting (BIOMED) 2006
Roger J. Zemp
BWG4 Biomedical Optics (BIOMED) 2010