Nonanamorphic imaging with three conic mirrors

Not Accessible

Your library or personal account may give you access

Abstract

Design methods are described for unobstructed, plane-symmetric systems composed of three conic mirrors. Low order imaging constraints (including the requirement of nonanamorphism) are used to reduce the dimensionality of the configuration space. Examples are presented.