Sensitive label-free and compact biosensor based on concentric silicon-on-insulator microring resonators

Xiaohui Li, Ziyang Zhang, Shenying Qin, Tao Wang, Fangfei Liu, Min Qiu, and Yikai Su  »View Author Affiliations


Applied Optics, Vol. 48, Issue 25, pp. F90-F94 (2009)
http://dx.doi.org/10.1364/AO.48.000F90


View Full Text Article

Enhanced HTML    Acrobat PDF (621 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We propose an ultracompact parallel label-free biosensor based on concentric silicon-on-insulator microring resonators. Our numerical studies show that the proposed biosensor offers higher sensitivity and a larger detection area than conventional single-ring-based sensors. We analyze the detection sensitivity of the DNA hybridization by immobilizing the probe on top of the double concentric ring resonators and in the ring–ring air gap. For a concentric double-ring system with an area of 27.646 μm 2 , the bulk detection sensitivity is 683 nm RIU 1 . The sensitive uniformity of the system related to the optical field distribution is also studied.

© 2009 Optical Society of America

OCIS Codes
(130.6010) Integrated optics : Sensors
(230.4555) Optical devices : Coupled resonators

ToC Category:
Photonic Integration

History
Original Manuscript: February 2, 2009
Revised Manuscript: June 12, 2009
Manuscript Accepted: July 5, 2009
Published: July 21, 2009

Virtual Issues
Vol. 4, Iss. 11 Virtual Journal for Biomedical Optics

Citation
Xiaohui Li, Ziyang Zhang, Shenying Qin, Tao Wang, Fangfei Liu, Min Qiu, and Yikai Su, "Sensitive label-free and compact biosensor based on concentric silicon-on-insulator microring resonators," Appl. Opt. 48, F90-F94 (2009)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-48-25-F90


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. O. Lazcka, F. J. Del Campo, and F. X. Munoz, “Pathogen detection: a perspective of traditional methods and biosensors,” Biosens. Bioelectron. 22, 1205-1217 (2007). [CrossRef]
  2. P. P. P. Debackere, S. Scheerlinck, P. Bienstman, and R. Baets, “Surface plasmon interferometer in silicon-on-insulator: novel concept for an integrated biosensor,” Opt. Express 14, 7063-7072 (2006). [CrossRef] [PubMed]
  3. A. Ymeti, J. Greve, P. V. Lambeck, T. Wink, S. W. F. M. van Hövell, T. A. M. Beumer, R. R. Wijn, R. G. Heideman, V. Subramaniam, and J. S. Kanger, “Fast, ultrasensitive virus detection using a Young interferometer sensor,” Nano. Lett. 7, 394-397 (2007). [CrossRef] [PubMed]
  4. Y. Li and L. Tong, “Mach--Zehnder interferometers assembled with optical microfibers or nanofibers,” Opt. Lett. 33, 303-305 (2008). [CrossRef] [PubMed]
  5. X. Guo and L. Tong, “Supported microfiber loops for optical sensing,” Opt. Express 16, 14429-14434 (2008). [CrossRef] [PubMed]
  6. A. Ksendzov and Y. Lin, “Integrated optics ring-resonator sensors for protein detection,” Opt. Lett. 30, 3344-3346 (2005). [CrossRef]
  7. A. Ksendzov, M. L. Homer, and A. M. Manfreda, “Integrated optics ring-resonator chemical sensor with polymer transduction layer,” Electron. Lett. 40, 63-65 (2004). [CrossRef]
  8. K. D. Vos, I. Bartolozzi, E. Schacht, P. Bienstman, and R. Baets, “Silicon-on-insulator microring resonator for sensitive and label-free biosensing,” Opt. Express 15, 7610-7615 (2007). [CrossRef] [PubMed]
  9. B. E. Little, S. T. Chu, H. A. Haus, J. Foresi, and J. P. Laine, “Microring resonator channel dropping filters,” J. Lightwave Technol. 15, 998-1005 (1997). [CrossRef]
  10. C. Manolatou, M. J. Khan, S. Fan, P. R. Villeneuve, H. A. Haus, and J. D. Joannopoulos, “Coupling of modes analysis of resonant channel add-drop filters,” IEEE J. Quantum Electron. 35, 1322-1331 (1999). [CrossRef]
  11. Z. Zhang, M. Dainese, L. Wosinski, and M. Qiu, “Resonance-splitting and enhanced notch depth in SOI ring resonators with mutual mode coupling,” Opt. Express 16, 4621-4630(2008). [CrossRef] [PubMed]
  12. X. Li, Z. Zhang, Q. Yin, M. Qiu, and Y. Su, “Concentric silicon micro-ring resonators with enhanced transmission notch depth,” in Proceedings of the Asia- Pacific Optical Communications Conference (APOC) (SPIE, 2008), 7135-25.
  13. X. Li, Z. Zhang, Q. Li, M. Qiu, and Y. Su, “Label-free biosensor based on silicon-on-insulator concentric micro-ring resonators,” in Proceedings of the IEEE Photonics Global Conference (IEEE, 2008).
  14. S. Elhadj, G. Singh, and R. F. Saraf, “Optical properties of an immobilized DNA monolayer from 255 to 700 nm,” Langmuir 20, 5539-5543 (2004). [CrossRef]
  15. S. Mandal and D. Erickson, “Nanoscale optofluidic sensor arrays,” Opt. Express 16, 1623-1631 (2008). [CrossRef] [PubMed]
  16. X. Li, Z. Zhang, Q. Yin, M. Qiu, and Y. Su, “Ultra-compact parallel label-free biosensors based on concentric micro-ring resonators in silicon-on-insulator,” in Proceedings of the Asia Optical Fiber and Optoelectronic 2008 Exposition and Conference (IEEE, 2008).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited