Cavity length measurement: bias from misalignment and mismatching

Not Accessible

Your library or personal account may give you access

Abstract

SR-POEM, the sounding rocket principle of equivalence measurement, uses a set of six tracking-frequency laser gauges operating in Fabry–Perot cavities to determine the relative acceleration of two test masses (TMs) that are chemically different. One end of each cavity is a flat mirror on a TM; the other end is a concave coupling mirror mounted to a common reference plate. The tracking-frequency laser gauges work by locking a variable frequency laser to the cavity by the method of Pound, Drever, and Hall. Because the TMs are unconstrained, they are expected to rotate slightly during measurement. Although the distance measurements are intended to be based on the TEM00 cavity mode, any misalignment will couple into higher-order transverse modes, particularly the TEM10 and TEM01. Light thus coupled will contribute a spurious signal to the cavity locking servo that causes a bias (i.e., a systematic error) in the length determination. The spurious signal proportional to the misalignment has an antisymmetric distribution at the detector and thus has a zero average, but causes a distance bias because of the inhomogeneity of the detector responsivity. To prevent such bias, SR-POEM includes a servo to keep the incoming laser beam aligned with the cavity. The required performance of that alignment servo is less stringent than has already been achieved by other projects. There is also a spurious signal proportional to the square of the misalignment that produces a symmetric distribution at the detector. This signal is also made unimportant by the operation of an alignment servo, even when operating well above the shot noise limit. We also look at the locking of a laser to a high finesse cavity and conclude that the alignment quality sets a bound on the ratio of measurement accuracy to cavity linewidth.

Full Article  |  PDF Article
More Like This
Aligning a reflection cavity by Anderson’s method

Robert D. Reasenberg
Appl. Opt. 51(16) 3132-3136 (2012)

Cavity mode-width spectroscopy with widely tunable ultra narrow laser

Agata Cygan, Daniel Lisak, Piotr Morzyński, Marcin Bober, Michał Zawada, Eugeniusz Pazderski, and Roman Ciuryło
Opt. Express 21(24) 29744-29754 (2013)

Equivalent path lengths in an integrating cavity: comment

Edward S. Fry, George W. Kattawar, Benjamin D. Strycker, and Peng-Wang Zhai
Appl. Opt. 49(4) 575-577 (2010)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (1)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (46)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved