Abstract
The radiant exposure of optical irradiation beams with different scanning parameters has been theoretically studied. We analyzed the difference in radiant exposure introduced by Gaussian and top hat beams. Various parameters such as scanning pattern, aperture position, beam size and scan spacing were also introduced in this study. We found that Gaussian beams introduce higher calculated radiant exposure to the aperture than top hat beams for certain beam size to aperture size ratios. However, as the scan spacing decreases, the radiant exposure difference calculated from Gaussian and top hat beams diminishes.