Abstract
Tunable UV filters for the 230–370-nm spectral range are described. The design and measurements of bandwidth and transmission are communicated. For a filter centered at 250 nm the full halfwidth and transmission amount to 6.5 nm and 14%, respectively.
© 1987 Optical Society of America
Full Article | PDF ArticleMore Like This
K. Balasubramanian, M. R. Jacobson, and H. A. Macleod
Appl. Opt. 31(10) 1574-1587 (1992)
Jian Li, N. Goddard, and Kang Xie
J. Opt. Soc. Am. A 27(1) 100-108 (2010)
Kang Xie, Dianguo Ma, Ji Ma, Lanju Liang, Dequan Wei, Xueqin Wang, Meng Wang, Zhijia Hu, Junxi Zhang, and Qiuping Mao
J. Opt. Soc. Am. A 39(3) 431-439 (2022)