OSA's Digital Library

Applied Optics

Applied Optics

APPLICATIONS-CENTERED RESEARCH IN OPTICS

  • Vol. 31, Iss. 1 — Jan. 1, 1992
  • pp: 69–74

Line-shape distortions in misaligned cube corner interferometers

Jyrki Kauppinen and Pekka Saarinen  »View Author Affiliations


Applied Optics, Vol. 31, Issue 1, pp. 69-74 (1992)
http://dx.doi.org/10.1364/AO.31.000069


View Full Text Article

Enhanced HTML    Acrobat PDF (483 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Line-shape distortions caused by the misalignment of the moving cube mirror in Fourier transform spectrometers have been described. A method of studying and correcting these distortions is presented. By using this method we can estimate the accuracy of the line position, which is especially important in high-resolution Fourier transform spectroscopy. The method is verified in simulations, and in practice it has been used to align the Oulu Fourier transform spectrometer.

© 1992 Optical Society of America

History
Original Manuscript: November 21, 1989
Published: January 1, 1992

Citation
Jyrki Kauppinen and Pekka Saarinen, "Line-shape distortions in misaligned cube corner interferometers," Appl. Opt. 31, 69-74 (1992)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-31-1-69


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. M. V. R. K. Murty, “Some more aspects of the Michelson interferometer with cube corners,” J. Opt. Soc. Am. 50, 7–10 (1960). [CrossRef]
  2. J. Kauppinen, T. Kärkkäinen, E. Kyrö, “Correcting errors in the optical path difference in Fourier spectroscopy: a new accurate method,” Appl. Opt. 17, 1587–1594 (1978). [CrossRef] [PubMed]
  3. J. Kauppinen, “Double-beam high resolution Fourier spectrometer for the far infrared,” Appl. Opt. 14, 1987–1992 (1975). [CrossRef] [PubMed]
  4. J. Kauppinen, “Working resolution of 0.010 cm−1 between 20 cm−1 and 1200 cm−1 by a Fourier spectrometer,” Appl. Opt. 18, 1788–1796 (1979). [CrossRef] [PubMed]
  5. J. Kauppinen, V.-M. Horneman, “Cube corner interferometer with the resolution of about 0.001 cm−1,” in Technical Digest of the Ninth Colloquium on High Resolution Spectroscopy, Riccione, Italy, 16–20 September 1985 (Cooperativa Libraria Universitaria Editrice, Bologna, 1985); J. Kauppinen, V.-M. Horneman, “Large aperture cube corner interferometer with a resolution of 0.001 cm−1,” Appl. Opt. 30, 2575–2578 (1991). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited