OSA's Digital Library

Applied Optics

Applied Optics

APPLICATIONS-CENTERED RESEARCH IN OPTICS

  • Vol. 38, Iss. 12 — Apr. 20, 1999
  • pp: 2432–2439

Comparison of Spectral Irradiance Standards Used to Calibrate Shortwave Radiometers and Spectroradiometers

Piotr W. Kiedron, Joseph J. Michalsky, Jerry L. Berndt, and Lee C. Harrison  »View Author Affiliations


Applied Optics, Vol. 38, Issue 12, pp. 2432-2439 (1999)
http://dx.doi.org/10.1364/AO.38.002432


View Full Text Article

Acrobat PDF (702 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Absolute calibration of spectral shortwave radiometers is usually performed with National Institute of Standards and Technology (NIST) or NIST-traceable incandescent lamps. We compare 18 irradiance standards from NIST and three commercial vendors using the same spectrometer to assess their agreement with our working standard. The NIST procedure is followed for the 1000-W FEL lamps from NIST, Optronics, and EG&G. A modified calibration procedure developed by Li-Cor is followed for their 200-W tungsten–halogen lamps. Results are reproducible from one day to the next to approximately 0.1% using the same spectrometer. Measurements taken four months apart using two similar but different spectrometers were reproducible to 0.5%. The comparisons suggest that even NIST standards may disagree with each other beyond their stated accuracy. Some of the 1000-W commercial lamps agreed with the NIST lamps to within their stated accuracy, but not all. Surprisingly, the lowest-cost lamps from Li-Cor agreed much better with the NIST lamps than their stated accuracy of 4%, typically within 2%. An analysis of errors leads us to conclude that we can transfer the calibration from a standard lamp to a secondary standard lamp with approximately 1% added uncertainty. A field spectrometer was calibrated with a secondary standard, producing a responsivity for the spectrometer that was within 5% of the responsivity obtained by Langley calibration using routine field measurements.

© 1999 Optical Society of America

OCIS Codes
(040.5160) Detectors : Photodetectors
(120.3940) Instrumentation, measurement, and metrology : Metrology
(120.5630) Instrumentation, measurement, and metrology : Radiometry
(120.6200) Instrumentation, measurement, and metrology : Spectrometers and spectroscopic instrumentation
(230.6080) Optical devices : Sources
(350.4800) Other areas of optics : Optical standards and testing

Citation
Piotr W. Kiedron, Joseph J. Michalsky, Jerry L. Berndt, and Lee C. Harrison, "Comparison of Spectral Irradiance Standards Used to Calibrate Shortwave Radiometers and Spectroradiometers," Appl. Opt. 38, 2432-2439 (1999)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-38-12-2432


Sort:  Author  |  Year  |  Journal  |  Reset

References

  1. G. M. Stokes and S. E. Schwartz, “The atmospheric radiation measurement (ARM) program: programmatic background and design of the cloud and radiation test bed,” Bull. Am. Meteorol. Soc. 75, 1201–1221 (1994).
  2. T. P. Charlock and T. L. Alberta, “CERES/ARM/GEWEX experiment (CAGEX) for the retrieval of radiative fluxes with satellite data,” Bull. Am. Meterol. Soc. 77, 2673–2683 (1996).
  3. S. Kato, T. P. Ackerman, E. E. Clothiaux, J. H. Mather, G. G. Mace, M. L. Wesely, F. Murcray, and J. Michalsky, “Uncertainties in modeled and measured clear-sky surface shortwave irradiances,” J. Geophys. Res. 102, 25,881–25,898 (1997).
  4. J. H. Walker, R. D. Saunders, J. K. Jackson, and D. A. McSparron, “Spectral irradiance calibrations,” NBS Measurement Services SP 250–20 (National Bureau of Standards, Gaithersburg, Md., 1987).
  5. EG&G Gamma Scientific, Inc., “Instruction manual for 5000 series lamp standards and 5000–6 lamp housing,” (San Diego, Calif., 1992).
  6. Li-Cor, Inc., “1800–02 optical radiation calibrator instruction manual,” (P. O. Box 4425, Lincoln, Neb. 68504, 1990).
  7. Optronics Laboratories, Inc., “Instructions for the Optronics Laboratories 1000-W FEL tungsten-halogen lamp standards of total and spectral irradiance,” (Orlando, Fla., 1995).
  8. L. Harrison, M. Beauharnois, J. Berndt, P. Kiedron, J. Michalsky, and Q. Min, “The rotating shadowband spectroradiometer (RSS) at SGP,” Geophys. Res. Lett. (to be published).
  9. K. D. Mielenz, R. D. Saunders, A. C. Parr, and J. J. Hsia, “The 1990 NIST scales of thermal radiometry,” J. Res. Natl. Inst. Stand. Technol. 95, 621–629 (1990).
  10. C. Wehrli, “Extraterrestrial solar spectrum,” Publication 615 (Physikalisch-Meterologisches Observatorium Davos and World Radiation Center, Davos-Dorf, Switzerland, 1985).
  11. R. L. Kurucz, “The solar irradiance by computation,” in Proceedings of the 17th Annual Conference on Atmospheric Transmission Models, PL-TR-95–2060, G. P. Anderson, R. H. Picard, and J. H. Chetwynd, eds. (Phillips Laboratory Directorate of Geophysics, Hanscom Air Force Base, Mass., 1995), pp. 333–334.
  12. J. A. Reagan, P. A. Pilewskie, I. C. Scott-Fleming, B. M. Herman, and A. Ben-David, “Extrapolation of Earth-based solar irradiance measurements to exoatmospheric levels for broad-band and selected absorption-band observations,” IEEE Trans. Geosci. Remote Sensing GE-25, 647–653 (1987).
  13. B. Schmid, P. R. Spyak, S. F. Biggar, C. Wehrli, J. Sekler, T. Ingold, C. Mätzler, and N. Kämpfer, “Evaluation of the applicability of solar and lamp radiometric calibrations of a precision Sun photometer operating between 300 and 1025 nm,” Appl. Opt. 37, 3923–3941 (1998).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited