OSA's Digital Library

Applied Optics

Applied Optics

APPLICATIONS-CENTERED RESEARCH IN OPTICS

  • Vol. 40, Iss. 22 — Aug. 1, 2001
  • pp: 3668–3676

Effects of a Small Inclination Misalignment in Talbot Interferometry by use of Gratings with Arbitrary Line Orientation. I. Theoretical Analysis

Qian Liu and Ryoji Ohba  »View Author Affiliations


Applied Optics, Vol. 40, Issue 22, pp. 3668-3676 (2001)
http://dx.doi.org/10.1364/AO.40.003668


View Full Text Article

Acrobat PDF (193 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We discuss the effects of a general small inclination misalignment, which is formed by rotation of the beam-splitter grating around an axis that is laid on the grating plane and that has an arbitrary angle with respect to the line direction of the grating, between the two grating planes on the moiré fringes in Talbot interferometry. It is shown that the small inclination angle has a significant influence on measurement results based on Talbot interferometry because both the period and the slope of the moiré fringes are sensitive to the angle, especially when the rotation axis is nearly parallel to the lines of the grating. Simple and practical detection methods for the small inclination angle are proposed, and the effects of the inclination angle on the contrast in the moiré fringes are also briefly discussed.

© 2001 Optical Society of America

OCIS Codes
(120.1880) Instrumentation, measurement, and metrology : Detection
(120.2650) Instrumentation, measurement, and metrology : Fringe analysis
(120.3180) Instrumentation, measurement, and metrology : Interferometry
(120.4120) Instrumentation, measurement, and metrology : Moire' techniques

Citation
Qian Liu and Ryoji Ohba, "Effects of a Small Inclination Misalignment in Talbot Interferometry by use of Gratings with Arbitrary Line Orientation. I. Theoretical Analysis," Appl. Opt. 40, 3668-3676 (2001)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-40-22-3668


Sort:  Author  |  Year  |  Journal  |  Reset

References

  1. K. Patorski, “Talbot interferometry with increased shear,” Appl. Opt. 24, 4448–4453 (1985).
  2. K. Patorski, “Talbot interferometry with increased shear: further considerations,” Appl. Opt. 25, 1111–1116 (1986).
  3. Q. Liu and R. Ohba, “Effects of unparallel grating planes in Talbot interferometry,” Appl. Opt. 38, 4111–4116 (1999).
  4. Q. Liu and R. Ohba, “Effects of unparallel grating planes in Talbot interferometry. II,” Appl. Opt. 39, 2084–2090 (2000).
  5. M. P. Kothiyal and K. V. Sriram, “Improved collimating testing using Talbot interferometer,” Appl. Opt. 26, 4056–4057 (1987).
  6. M. P. Kothiyal, K. V. Sriram, and R. S. Sirohi, “Setting sensitivity in Talbot interferometry,” Opt. Laser Technol. 23, 361–365 (1991).
  7. K. V. Sriram, M. Kothiyal, and R. S. Sirohi, “Direct determination of focal length by using Talbot interferometry,” Appl. Opt. 31, 5984–5987 (1992).
  8. M. P. Kothiyal, R. S. Sirohi, and K. J. Rosenbruch, “Improved techniques of collimating testing,” Opt. Laser Technol. 20, 139–144 (1991).
  9. Y. Nakano and K. Murata, “Talbot interferometry for measuring the small tilt angle of an object surface,” Appl. Opt. 25, 2475–2477 (1986).
  10. Y. Nakano, “Measurement of the small tilt-angle variation of an object surface using moiré interferometry and digital image processing,” Appl. Opt. 26, 3911–3914 (1987).
  11. H. Canabal, J. A. Quiroga, and E. Bernabeu, “Improved phase-shifting method for automatic processing deflectograms,” Appl. Opt. 37, 6227–6233 (1998).
  12. J. Striker, “Performance of moiré deflectometry with deferred electronic heterodyne readout,” J. Opt. Soc. Am. A 4, 42–50 (1987).
  13. S. Yokozeki and T. Suzuki, “Shearing interferometer using the grating as the beam splitter,” Appl. Opt. 10, 1575–1580 (1971).
  14. K. Patorski, “Fresnel diffraction field (self-imaging) of obliquely illuminated liner diffraction gratings,” Optik 69, 30–36 (1984).
  15. Q. Liu and R. Ohba, “Effects of a small inclination alignment in Talbot interferometry by use of gratings with arbitrary line orientation. II. Experimental verification,” Appl. Opt. (to be published).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited