Intercalibration Method for Underwater Three-Dimensional Mapping Laser Line Scan Systems

Karl D. Moore  »View Author Affiliations


Applied Optics, Vol. 40, Issue 33, pp. 5991-6004 (2001)
http://dx.doi.org/10.1364/AO.40.005991


View Full Text Article

Acrobat PDF (1931 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

I present a method to calibrate absolutely a new family of underwater bathymetric laser scanner systems that use a single target range. Depth is calculated by triangulation among the source, the receiver, and the instantaneous position of a single spot produced by a highly collimated laser beam scanned across the target. For calibration, the refractive index of seawater is used to modulate the triangulation parameters rather than use of different target ranges to calibrate for extended range operation. Exploitation of a unique triangulation configuration allows the receiver characteristics to be ignored initially so that the scanner parameters can be determined. This allows the accurate positioning of the laser spot so that the receiver, in turn, can be calibrated. This intercalibration method provides high-resolution parameterization of the source–receiver characteristics and their geometric layout within the system so that an absolute bathymetric calibration can be realized in situ. In addition, a theoretical model derived to develop the methodology can be used to characterize and optimize future designs.

© 2001 Optical Society of America

OCIS Codes
(010.4450) Atmospheric and oceanic optics : Oceanic optics
(120.4570) Instrumentation, measurement, and metrology : Optical design of instruments
(120.5800) Instrumentation, measurement, and metrology : Scanners
(150.6910) Machine vision : Three-dimensional sensing
(280.3400) Remote sensing and sensors : Laser range finder

Citation
Karl D. Moore, "Intercalibration Method for Underwater Three-Dimensional Mapping Laser Line Scan Systems," Appl. Opt. 40, 5991-6004 (2001)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-40-33-5991


Sort:  Author  |  Year  |  Journal  |  Reset

References

  1. R. Farcy and R. Damaschini, “Triangulating laser profilometer as a three-dimensional space perception system for the blind,” Appl. Opt. 36, 8227–8232 (1997).
  2. R. W. McCullough, P. D. Bondurant, and J. L. Doyle, “Laser-optical triangulation systems provide new capabilities for remote inspection of interior surfaces,” Mater. Eval. 53, 1338–1345 (1995).
  3. M. F. M. Costa, “Surface inspection by an optical triangulation method,” Opt. Eng. 35, 2743–2747 (1996).
  4. J. A. Jalkio, R. C. Kim, and S. K. Case, “Three-dimensional inspection using multistripe structured light,” Opt. Eng. 24, 966–974 (1985).
  5. J. Clark, A. M. Wallace, and G. L. Pronzato, “Measuring range using a triangulation sensor with variable geometry,” IEEE Trans. Rob. Autom. 14, 60–68 (1998).
  6. G. Häuser and M. Maul, “Telecentric scanner for 3-D sensing,” Opt. Eng. 24, 978–980 (1985).
  7. G. Bickel, G. Häuser, and M. Maul, “Triangulation with expanded range of depth,” Opt. Eng. 24, 975–977 (1985).
  8. K. D. Moore, J. S. Jaffe, and B. L. Ochoa, “Development of new underwater bathymetric laser imaging system: L-Bath,” J. Atmos. Oceanic Technol. 17, 1106–1117 (2000).
  9. R. W. Austin, S. Q. Duntley, R. L. Ensminger, T. J. Petzold, and R. C. Smith, “An underwater laser scanning system,” in Underwater Imaging, Photography, and Visibility, R. W. Spinrad, ed., Proc. SPIE 1537, 57–73 (1991).
  10. T. J. Kulp, D. Garvis, R. Kennedy, T. Salmon, and K. Cooper, “Development and testing of a synchronous-scanning underwater imaging system capable of rapid two-dimensional frame imaging,” Appl. Opt. 32, 3520–3530 (1993).
  11. J. S. Chu and I. R. MacDonald, “Underwater survey operations SM2000 laser line scan technology,” in Proceedings of the Autonomous Vehicles in Mine Countermeasures Symposium (Naval Postgraduate School, Monterey, Calif., 1995), pp. 6–82–6–90.
  12. M. P. Strand, B. W. Coles, A. J. Nevis, and R. Reagan, “Laser line scan fluorescence and multi-spectral imaging of coral reef environments,” in Ocean Optics XIII, S. G. Ackleson, ed., Proc. SPIE 2963, 790–795 (1996).
  13. B. Coles, “Laser line scan systems as environmental survey tools,” Ocean News Technol. 3, 22–24 (1997).
  14. J. W. McLean and J. T. Murray, “Streak-tube lidar allows 3-D ocean surveillance,” Laser Focus World 34, 171–172, 174 (1998).
  15. J. A. Beraldin, F. Blais, M. Rioux, L. Cournoyer, D. Laurin, and S. G. MacLean, “Eye-safe digital 3-D sensing for space applications,” Opt. Eng. 39, 196–211 (2000).
  16. R. Baribeau and M. Rioux, “Influence of speckle on laser range finders,” Appl. Opt. 30, 2873–2878 (1991).
  17. H. Wang and D. Malacara, “Optical triangulation: a dual-channel configuration,” Rev. Sci. Instrum. 67, 2606–2611 (1996).
  18. L. Zeng, H. Matsumoto, and K. Kawachi, “Two directional scanning method for reducing the shadow effects in laser triangulation,” Meas. Sci. Technol. 8, 262–266 (1997).
  19. F. M. Caimi and D. M. Kocak, “Real-time 3D underwater imaging and mapping using a laser line scan technique,” in Optical Scanning Systems: Design and Applications, L. Beiser and S. F. Sagan, eds., Proc. SPIE 3131, 241–252 (1997).
  20. S. Tetlow and J. Spours, “Three-dimensional measurement of underwater work sites using structured laser light,” Meas. Sci. Technol. 10, 1162–1167 (1999).
  21. J. M. Sasian, “Image plane tilt in optical systems,” Opt. Eng. 31, 527–532 (1992).
  22. M. J. Chantler, J. Clark, and M. Umasuthan, “Calibration and operation of an underwater laser triangulation sensor: the varying baseline problem,” Opt. Eng. 36, 2604–2611 (1997).
  23. The voltage positional encoder of the galvanometrically driven scanner has an angular accuracy of ∓0.005°. Because this encoder voltage is digitized at 12 bits over the voltage range of ∓10.0 V, the smallest digital increment equates to 0.0195°, i.e., Δφsz = ∓0.01°. Therefore we can assume that the digitizer limits the scanner accuracy if no other noise sources are included.
  24. R. W. Schmitt, P. S. Bogden, and C. E. Dorman, “Evaporation minus precipitation and density fluxes for the North Atlantic,” J. Phys. Oceanogr. 19, 1208–1221 (1989).
  25. X. Quan and E. S. Fry, “Empirical equation for the refractive index of seawater,” Appl. Opt. 34, 3477–3480 (1995).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited