OSA's Digital Library

Applied Optics

Applied Optics

APPLICATIONS-CENTERED RESEARCH IN OPTICS

  • Editor: James C. Wyant
  • Vol. 45, Iss. 6 — Feb. 20, 2006
  • pp: 1111–1119

Simple spectral stray light correction method for array spectroradiometers

Yuqin Zong, Steven W. Brown, B. Carol Johnson, Keith R. Lykke, and Yoshi Ohno  »View Author Affiliations


Applied Optics, Vol. 45, Issue 6, pp. 1111-1119 (2006)
http://dx.doi.org/10.1364/AO.45.001111


View Full Text Article

Enhanced HTML    Acrobat PDF (843 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A simple, practical method has been developed to correct a spectroradiometer's response for measurement errors arising from the instrument's spectral stray light. By characterizing the instrument's response to a set of monochromatic laser sources that cover the instrument's spectral range, one obtains a spectral stray light signal distribution matrix that quantifies the magnitude of the spectral stray light signal within the instrument. By use of these data, a spectral stray light correction matrix is derived and the instrument's response can be corrected with a simple matrix multiplication. The method has been implemented and validated with a commercial CCD-array spectrograph. Spectral stray light errors after the correction was applied were reduced by 1–2 orders of magnitude to a level of approximately 10 5 for a broadband source measurement, equivalent to less than one count of the 15-bit-resolution instrument. This method is fast enough to be integrated into an instrument's software to perform real-time corrections with minimal effect on acquisition speed. Using instruments that have been corrected for spectral stray light, we expect significant reductions in overall measurement uncertainties in many applications in which spectrometers are commonly used, including radiometry, colorimetry, photometry, and biotechnology.

© 2006 Optical Society of America

OCIS Codes
(120.5240) Instrumentation, measurement, and metrology : Photometry
(120.5630) Instrumentation, measurement, and metrology : Radiometry
(120.6200) Instrumentation, measurement, and metrology : Spectrometers and spectroscopic instrumentation
(300.6190) Spectroscopy : Spectrometers
(330.1710) Vision, color, and visual optics : Color, measurement

ToC Category:
Instrumentation, Measurement, and Metrology

History
Original Manuscript: June 10, 2005
Revised Manuscript: September 24, 2005
Manuscript Accepted: September 27, 2005

Virtual Issues
Vol. 1, Iss. 3 Virtual Journal for Biomedical Optics

Citation
Yuqin Zong, Steven W. Brown, B. Carol Johnson, Keith R. Lykke, and Yoshi Ohno, "Simple spectral stray light correction method for array spectroradiometers," Appl. Opt. 45, 1111-1119 (2006)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-45-6-1111


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. T. N. Woods R.T Wrigley III, G. J. Rottman, and R. E. Haring, "Scattered light properties of diffraction gratings," Appl. Opt. 33, 4273-4285 (1994). [CrossRef] [PubMed]
  2. H. J. Kostkowski, ed., "Spectral scattering," in Reliable Spectroradiometry (Spectroradiometry Consulting, La Plata, Md., 1997), pp. 57-87.
  3. S. W. Brown, B. C. Johnson, M. E. Feinholz, M. A. Yarbrough, S. J. Flora, K. R. Lykke, and D. K. Clark, "Stray light correction algorithm for spectrographs," Metrologia 40, S81-83 (2003). [CrossRef]
  4. S. W. Brown, D. K. Clark, B. C. Johnson, H. Yoon, K. R. Lykke, S. J. Flora, M. E. Feinholz, N. Souaidia, C. Pietras, T. C. Stone, M. A. Yarbrough, Y. S. Kim, R. A. Barnes, and J. L. Mueller, "Advances in radiometry for ocean color," Chap. 7 of Special Topics in Ocean Optics Protocols, Part 2 of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Rev. 5, Vol. VI, J. L. Mueller, G. S. Fargion, and C. R. McClain, eds. (NASA Goddard Space Flight Center, 2004), pp. 8-35.
  5. C. B. Moler, ed., "Linear equations," in Numerical Computing with Matlab (Society for Industrial and Applied Mathematics, 2004), pp. 53-92.
  6. S. W. Brown, G. P. Eppeldauer, and K. R. Lykke, "NIST facility for spectral irradiance and radiance responsivity calibrations with uniform sources," Metrologia 37, 579-582 (2000). [CrossRef]
  7. Richard Young, Optronic Laboratories, Inc., 4632 36th Street, Orlando, Fla. 32811 (personal communication, 2004).
  8. Dennis K. Clark, National Oceanic and Atmospheric Administration, NOAA/NESDIS, 5200 Auth Rd., Camp Springs, MD 20746 (personal communication, 2004).
  9. CIE Technical Committee 1-48, "Recommendations concerning the calculation of tristimulus values and chromaticity coordinates," in Colorimetry, CIE Tech. Rep. CIE 15:2004, 3rd ed. (Commission Internationale de l'Eclairage, 2004), pp. 12-16.
  10. Y. Zong, C. C. Miller, K. R. Lykke, and Y. Ohno, "Measurement of total radiant flux of UV LEDs," in Proceedings of the CIE Symposium '04, LED Light Sources: Physical Measurement and Visual and Photobiological Assessment, CIE publ. x026:2004 (Commission Internationale de l'Eclairage, 2004), pp. 107-110.

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited