Chemical concentration measurement in blood serum and urine samples using liquid-core optical fiber Raman spectroscopy

Dahu Qi and Andrew J. Berger  »View Author Affiliations


Applied Optics, Vol. 46, Issue 10, pp. 1726-1734 (2007)
http://dx.doi.org/10.1364/AO.46.001726


View Full Text Article

Enhanced HTML    Acrobat PDF (652 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We report measurements of chemical concentrations in clinical blood serum and urine samples using liquid-core optical fiber (LCOF) Raman spectroscopy to increase the collected signal strength. Both Raman and absorption spectra were acquired in the near-infrared region using the LCOF geometry. Spectra of 71 blood serum and 61 urine samples were regressed via partial least squares against reference analyzer values. Significant correlation was found between predicted and reference concentrations for 13 chemicals. Using absorption data to normalize the LCOF enhancement made the results more accurate. The experimental geometry is well suited for high-volume and automated chemical analysis of clear biofluids.

© 2007 Optical Society of America

OCIS Codes
(170.5660) Medical optics and biotechnology : Raman spectroscopy
(300.6450) Spectroscopy : Spectroscopy, Raman

ToC Category:
Optical spectroscopic imaging and diagnostics

History
Original Manuscript: March 31, 2006
Revised Manuscript: September 24, 2006
Manuscript Accepted: November 16, 2006
Published: March 13, 2007

Virtual Issues
Vol. 2, Iss. 5 Virtual Journal for Biomedical Optics

Citation
Dahu Qi and Andrew J. Berger, "Chemical concentration measurement in blood serum and urine samples using liquid-core optical fiber Raman spectroscopy," Appl. Opt. 46, 1726-1734 (2007)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-46-10-1726


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. A. M. K. Enejder, T.-W. Koo, J. Oh, M. Hunter, S. Sasic, M. S. Feld, and G. L. Horowitz, "Blood analysis by Raman spectroscopy," Opt. Lett. 27, 2004-2007 (2002). [CrossRef]
  2. W. R. Premasiri, R. H. Clarks, and M. E. Womble, "Urine analysis by laser Raman spectroscopy," Lasers Surg. Med. 28, 330-334 (2001). [CrossRef] [PubMed]
  3. K. J. Ward, D. M. Haaland, M. R. Robinson, and R. P. Eaton, "Post-prandial blood glucose determination by quantitative mid-infrared spectroscopy," Appl. Spectrosc. 46, 959-965 (1992). [CrossRef]
  4. H. M. Heise, R. Marbach, T. Koshinsky, and F. A. Gries, "Multicomponent assay for blood substrates in human plasma by mid-infrared spectroscopy and its evaluation for clinical analysis," Appl. Spectrosc. 48, 85-95 (1994). [CrossRef]
  5. G. Budinova, J. Salva, and K. Volka, "Application of molecular spectroscopy in the mid-infrared region to the determination of glucose and cholesterol in whole blood and in blood serum," Appl. Spectrosc. 51, 631-635 (1997). [CrossRef]
  6. C. Petibois, V. Rigalleau, A.-M. Mellin, A. Perromat, G. Cazorla, H. Gin, and G. Deleris, "Determination of glucose in dried serum samples by Fourier-transform infrared spectroscopy," Clin. Chem. 45, 1530-1535 (1999). [PubMed]
  7. D. Rohleder, G. Kocherscheidt, W. K. K. Gerber, J. Möcks, and W. Petrich, "Comparison of mid-infrared and Raman spectroscopy in the quantitative analysis of serum," J. Biomed. Opt. 10, 031108 (2005). [CrossRef] [PubMed]
  8. R. A. Shaw, S. Low-Ying, M. Leroux, and H. H. Mantsch, "Toward reagent-free clinical analysis: quantitation of urine urea, creatinine, and total protein from the mid-infrared spectra of dried urine films," Clin. Chem. 46, 1493-1495 (2000). [PubMed]
  9. H. M. Heise, G. Voigt, P. Lampen, L. Kupper, S. Rudloff, and G. Werner, "Multivariate calibration for the determination of analytes in urine using mid-infrared attenuated total reflection spectroscopy," Appl. Spectrosc. 55, 434-443 (2001). [CrossRef]
  10. F. M. Ham, G. M. Cohen, I. Kostanic, and B. R. Gooch, "Multivariate determination of glucose concentrations from optimally filtered frequency-warped NIR spectra of human blood serum," Physiol. Meas. 17, 1-20 (1996). [CrossRef] [PubMed]
  11. R. E. Shaffer, G. W. Small, and M. A. Arnold, "Genetic algorithm-based protocol for coupling digital filtering and partial least-squares regression: application to the near-infrared analysis of glucose in biological matrices," Anal. Chem. 68, 2663-2675 (1996). [CrossRef] [PubMed]
  12. N. Kang, S. Kasemsumran, Y.-A. Woo, H.-J. Kim, and Y. Ozaki, "Optimization of informative spectral regions for the quantification of cholesterol, glucose and urea in control serum solutions using searching combination moving window partial least squares regression method with near infrared spectroscopy," Chemom. Intell. Lab. Syst. 82, 90-96 (2006). [CrossRef]
  13. S. Kasemsumran, Y. P. Du, K. Maruo, and Y. Ozaki, "Improvement of partial least squares models for in vitro and in vivo glucose quantifications by using near-infrared spectroscopy and searching combination moving window partial least squares," Chemom. Intell. Lab. Syst. 82, 97-103 (2006). [CrossRef]
  14. R. A. Shaw, S. Kotowich, H. H. Mantsch, and M. Leroux, "Quantitation of protein, creatinine, and urea in urine by near-infrared spectroscopy," Clin. Biochem. 29, 11-19 (1996). [CrossRef] [PubMed]
  15. A. J. Berger, T.-W. Koo, I. Itzkan, G. Horowitz, and M. S. Feld, "Multicomponent blood analysis by near-infrared Raman spectroscopy," Appl. Opt. 38, 2916-2926 (1999). [CrossRef]
  16. J. Y. Qu, B. C. Wilson, and D. Suria, "Concentration measurement of multiple analytes in human sera by near-infrared laser Raman spectroscopy," Appl. Opt. 38, 5491-5498 (1999). [CrossRef]
  17. J. Y. Qu and L. Shao, "Near-infrared Raman instrument for rapid and quantitative measurements of clinically important analytes," Rev. Sci. Instrum. 72, 2717-2723 (2001). [CrossRef]
  18. D. Rohleder, W. Kiefer, and W. Petrich, "Quantitative analysis of serum and serum ultrafiltrate by means of Raman spectroscopy," Analyst 10, 906-911 (2004). [CrossRef]
  19. J. W. McMurdy III and A. J. Berger, "Raman spectroscopy-based creatinine measurement in urine samples from a multipatient population," Appl. Spectrosc. 57, 522-525 (2003). [CrossRef] [PubMed]
  20. D. Qi and A. J. Berger, "Quantitative concentration measurements of creatinine dissovled in water and urine using Raman spectroscopy and a liquid core optical fiber," J. Biomed. Opt. 10, 031115 (2005). [CrossRef] [PubMed]
  21. L. Song, S. Liu, V. Zhelyaskov, and M. A. El-Sayed, "Application of liquid waveguide to Raman spectroscopy in aqueous solution," Appl. Spectrosc. 52, 1364-1367 (1998).
  22. R. Altkorn, I. Koev, and M. J. Pelletier, "Raman performance characteristics of Teflon-AF 2400 liquid-core optical-fiber sample cells," Appl. Spectrosc. 53, 1169-1176 (1999). [CrossRef]
  23. M. J. Pelletier and R. Altkorn, "Raman sensitivity enhancement for aqueous protein samples using a liquid-core optical-fiber cell," Anal. Chem. 73, 1393-1397 (2001). [CrossRef] [PubMed]
  24. D. Qi and A. J. Berger, "Quantitative analysis of Raman signal enhancement from aqueous samples in liquid core optical fibers," Appl. Spectrosc. 58, 1165-1171 (2004). [CrossRef] [PubMed]
  25. R. Altkorn, M. D. Malinsky, R. P. Van Duyne, and I. Koev, "Intensity considerations in liquid core optical fiber Raman spectroscopy," Appl. Spectrosc. 55, 373-381 (2001). [CrossRef]
  26. D. Qi and A. J. Berger, "Correction method for absorption-dependent signal enhancement by a liquid core optical fiber," Appl. Opt. 45, 489-494 (2006). [CrossRef] [PubMed]
  27. A. Savitzky and M. J. E. Golay, "Smoothing and differentiation of data by simplified least squares procedures," Anal. Chem. 36, 1627-1639 (1964). [CrossRef]
  28. C. A. Lieber and A. Mahadevan-Jansen, "Automated method for subtraction of fluorescence from biological Raman spectra," Appl. Spectrosc. 57, 1363-1367 (2003). [CrossRef] [PubMed]
  29. R. Altkorn, I. Koev, R. P. V. Duyne, and M. Litorja, "Low-loss liquid-core optical fiber for low-refractive-index liquids: fabrication, characterization, and application in Raman spectroscopy," Appl. Opt. 36, 8992-8998 (1997). [CrossRef]
  30. H. Mark, "Use of Mahalanobis distances to evaluate sample preparation for near-infrared reflectance analysis," Anal. Chem. 59, 790-795 (1987). [CrossRef]
  31. D. M. Haaland and E. V. Thomas, "Partial least-squares methods for spectral analysis. 1. Relation to other quantitative calibration methods and the extraction of quantitative information," Anal. Chem. 60, 1193-1202 (1988). [CrossRef]
  32. D. M. Haaland and E. V. Thomas, "Partial least-squares methods for spectral analysis. 2. Application to simulated and glass spectra data," Anal. Chem. 60, 1202-1208 (1988). [CrossRef]
  33. W. L. Clarke, D. Cox, L. A. Conder-Frederick, W. Carter, and S. L. Pohl, "Evaluating clinical accuracy of systems for self-monitoring of blood glucose," Diabetes Care 10, 622-628 (1987). [CrossRef] [PubMed]
  34. C. A. Burtis, E. R. Ashwood, and D. E. Bruns, eds., Tietz Textbook of Clinical Chemistry and Molecular Diagnosis, 4th ed. (Elsevier, 2006).
  35. J. McMorran, D. C. Crowther, S. McMorran, C. Prince, S. YoungMin, J. Pleat, and I. Wacogne, "General Practice Notebook" (Oxbridge Solution Ltd., UK, 2007), http://www.gpnotebook.co.uk.

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited