OSA's Digital Library

Applied Optics

Applied Optics

APPLICATIONS-CENTERED RESEARCH IN OPTICS

  • Editor: James C. Wyant
  • Vol. 47, Iss. 15 — May. 20, 2008
  • pp: 2767–2778

Enhanced x-ray resolving power achieved behind the focal circles of Cauchois spectrometers

John F. Seely, Lawrence T. Hudson, Glenn E. Holland, and Albert Henins  »View Author Affiliations


Applied Optics, Vol. 47, Issue 15, pp. 2767-2778 (2008)
http://dx.doi.org/10.1364/AO.47.002767


View Full Text Article

Enhanced HTML    Acrobat PDF (3258 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Maintaining high resolving power is a primary challenge in hard x-ray spectroscopy of newly developed bright and transient x-ray sources such as laser-produced plasmas. To address this challenge, the line widths in x-ray spectra with energies in the 17 keV to 70 keV range were recorded by positioning the detectors on and behind the focal circles of Cauchois type transmission-crystal spectrometers. To analyze and understand the observed line widths, we developed a geometrical model that accounts for source broadening and various instrumental broadening mechanisms. The x-ray sources were laboratory Mo or W electron-bombarded anodes, and the spectra were recorded on photostimulable phosphor image plates. For these relatively small x-ray sources, it was found that when the detector was placed on or near the focal circle, the line widths were dominated by the effective spatial resolution of the detector. When the detector was positioned beyond the focal circle, the line widths were determined primarily by source-size broadening. Moreover, the separation between the spectral lines increased with distance behind the focal circle faster than the line widths, resulting in increased resolving power with distance. Contributions to line broadenings caused by the crystal thickness, crystal rocking curve width, geometrical aberrations, and natural widths of the x-ray transitions were in all cases smaller than detector and source broadening, but were significant for some spectrometer geometries. The various contributions to the line widths, calculated using simple analytical expressions, were in good agreement with the measured line widths for a variety of spectrometer and source conditions. These modeling and experimental results enable the design of hard x-ray spectrometers that are optimized for high resolving power and for the measurement of the x-ray source size from the line widths recorded behind the focal circle.

© 2008 Optical Society of America

OCIS Codes
(300.3700) Spectroscopy : Linewidth

ToC Category:
Spectroscopy

History
Original Manuscript: November 7, 2007
Manuscript Accepted: February 16, 2008
Published: May 13, 2008

Citation
John F. Seely, Lawrence T. Hudson, Glenn E. Holland, and Albert Henins, "Enhanced x-ray resolving power achieved behind the focal circles of Cauchois spectrometers," Appl. Opt. 47, 2767-2778 (2008)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-47-15-2767


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. Y. Cauchois, “Spectrographie des rayons x par transmission d'un faisceau non canalise a travers un cristal courbe,” J. de Physique. 3320 (1932). English translation is available at http://spectroscopy.nrl.navy.mil/.
  2. A. Compton and S. Allison, X-Rays in Theory and Experiments (van Nostrand, 1935), p. 750.
  3. L. T. Hudson, A. Henins, J. F. Seely, and G. E. Holland, “Diagnostic spectrometers for high energy density x-ray sources,” in 15th International Conference on Atomic Processes in Plasmas, J. D. Gillaspy, J. J. Curry, and W. Wiese, eds. (American Institute of Physics, 2007, pp. 34-41.
  4. L. T. Hudson, A. Henins, R. D. Deslattes, J. F. Seely, G. E. Holland, R. Atkin, L. Martin, D. D. Meyerhofer, and C. Stoeckl, “A high-energy x-ray spectrometer diagnostic for the OMEGA laser,” Rev. Sci. Instrum. 73, 2270 (2002). [CrossRef]
  5. J. F. Seely, R. Doron, A. Bar-Shalom, L. T. Hudson, and C. Stoeckl, “Hard x-ray emission from laser-produced plasmas of U and Pb recorded by a transmission crystal spectrometer,” J. Quant. Spectrosc. Radiat. Transfer 81, 421 (2003). [CrossRef]
  6. J. F. Seely, C. A. Back, C. Constantin, R. W. Lee, H.-K. Chung, L. T. Hudson, C. I. Szabo, A. Henins, G. E. Holland, R. Atkin, and L. Martin, “Krypton K-shell x-ray spectra recorded by the HENEX spectrometer,” J. Quant. Spectrosc. Radiat. Transfer 99, 572 (2006). [CrossRef]
  7. L. T. Hudson, R. Atkin, C. A. Back, A. Henins, G. E. Holland, J. F. Seely, and C. Szabo, “X-ray spectroscopy at next-generation inertial confinement fusion sources: anticipating needs and challenges,” Radiat. Phys. Chem. 75, 1784 (2006). [CrossRef]
  8. C. I. Szabo, L. T. Hudson, A. Henins, G. E. Holland, R. Atkin, and J. F. Seely, “Mitigation of fluorescence and scattering in reflection convex-crystal x-ray spectrometers,” Radiat. Phys. Chem. 75, 1824 (2006). [CrossRef]
  9. J. F. Seely, G. Holland, L. Hudson, C. Szabo, A. Henins, H.-S. Park, P. Patel, R. Tommasini, and J. Laming, “K-shell spectra from Ag, Sn, Sm, Ta, and Au generated by intense fetmosecond laser pulses,” High Energy Density Phys. 3, 263 (2007). [CrossRef]
  10. R. D. Deslattes, J. C. Levin, M. D. Walker, and A. Henins, “Noninvasive high-voltage measurement in mammography by crystal diffraction spectroscopy,” Med. Phys. 21, 123 (1994). [CrossRef] [PubMed]
  11. C. T. Chantler, R. D. Deslattes, A. Henins, and L. T. Hudson, “Flat and curved crystal spectroscopy for mammographic x-ray sources,” Br. J. Radiol. 69, 636 (1996). [CrossRef] [PubMed]
  12. L. T. Hudson, R. D. Deslattes, A. Henins, C. T. Chantler, E. G. Kessler, and J. E. Schweppe, “A curved crystal spectrometer for energy calibration and spectral characterization of mammographic x-ray sources,” Med. Phys. 23, 1659 (1996). [CrossRef] [PubMed]
  13. J. A. R. Samson, Techniques of Vacuum Ultraviolet Spectroscopy (Wiley, 1967), p. 8.
  14. E. O. Baronova, M. M. Stepanenko, and N. R. Pereira, “Cauchois-Johansson x-ray spectrograph for 1.5-400 keV energy range,” Rev. Sci. Instrum. 72, 1416 (2001). [CrossRef]
  15. S. I. Salem and P. L. Lee, “Experimental widths of K and L x-ray lines,” At. Data Nucl. Data Tables 18, 233 (1976). [CrossRef]
  16. D. A. Lind, W. J. West, and J. W. M. DuMond, “X-ray and gamma-ray reflection properties from 500 x units to nine x units of unstressed and of bent quartz plates for use in the two-meter curved-crystal focusing gamma-ray spectrometer,” Phys. Rev. 77, 475 (1950). [CrossRef]
  17. P. Suortti, “Focusing monochromators for high energy synchrotron radiation,” Rev. Sci. Instrum. 63, 942 (1992). [CrossRef]
  18. E. Andersson, G. Hölzer, E. Förster, M. Grätz, L. Kiernan, A. Sjögren, and S. Svanberg, “Coronary angiography using laser plasma sources: x-ray source efficiency and optimization of a bent crystal monochromator,” J. Appl. Phys. 90, 3048(2001). [CrossRef]
  19. M. Sanchez del Rio and R. J. Dejus, “Computer simulation of bent perfect crystal diffraction profiles,” Proc. SPIE 3151, 312(1997). [CrossRef]
  20. S. Takagi, “A dynamical theory of diffraction for a distorted crystal,” J. Phys. Soc. Jpn. 29, 1239 (1969). [CrossRef]
  21. D. Taupin, “Theorie dynamique de la diffraction des rayons x par les crustaux deformes,” Bull. Soc. Fr. Mineral. Crystallogr. 87, 469 (1964).
  22. O. I. Sumbayev and A. I. Smirnov, “4-meter Cauchois spectrometer for neutron-capture gamma-radiation research,” Nucl. Instrum. Methods 22, 125 (1963). [CrossRef]
  23. R. D. Deslattes, E. G. Kessler, P. Indelicato, L. de Billy, E. Lindroth, and J. Anton, “X-ray transition energies: new approach to a comprehensive evaluation,” Rev. Mod. Phys. 75, 35 (2003). [CrossRef]
  24. H. H. Li, A. L. Gonzalez, H. Ji, and D. M. Duggan, “Dose response of BaFBrI:Eu storage phosphor plates exposed to megavoltage photon beams,” Med. Phys. 34, 103 (2007). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited