OSA's Digital Library

Applied Optics

Applied Optics

APPLICATIONS-CENTERED RESEARCH IN OPTICS

  • Editor: Joseph N. Mait
  • Vol. 49, Iss. 22 — Aug. 1, 2010
  • pp: 4193–4201

Microscope spectrometer for light scattering investigations

Aude Barbara, Tomas Lopez-Rios, Sylvain Dumont, Frédéric Gay, and Pascal Quémerais  »View Author Affiliations


Applied Optics, Vol. 49, Issue 22, pp. 4193-4201 (2010)
http://dx.doi.org/10.1364/AO.49.004193


View Full Text Article

Enhanced HTML    Acrobat PDF (505 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We describe a setup including a microscope to study volumes of a few μm 3 by static and dynamic light scattering (DLS) in a backscattering configuration. Light scattered by individual objects of micrometric size can be analyzed in the 400 800 nm spectral range. This setup can also be employed to study both diluted and concentrated colloidal solutions by DLS measurements. For diluted solutions we found evidence of the fluctuations of the number of particles in a confocal volume. We discuss their contribution to the autocorrelation function of the scattered intensity measured as a function of time.

© 2010 Optical Society of America

OCIS Codes
(120.4820) Instrumentation, measurement, and metrology : Optical systems
(290.5820) Scattering : Scattering measurements
(120.6165) Instrumentation, measurement, and metrology : Speckle interferometry, metrology

ToC Category:
Instrumentation, Measurement, and Metrology

History
Original Manuscript: April 12, 2010
Revised Manuscript: June 3, 2010
Manuscript Accepted: June 28, 2010
Published: July 27, 2010

Virtual Issues
Vol. 5, Iss. 12 Virtual Journal for Biomedical Optics

Citation
Aude Barbara, Tomas Lopez-Rios, Sylvain Dumont, Frédéric Gay, and Pascal Quémerais, "Microscope spectrometer for light scattering investigations," Appl. Opt. 49, 4193-4201 (2010)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-49-22-4193


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. R. A. Zsigmond, “Properties of colloids,” in Nobel Lectures in Chemistry 1922–1941 (Elsevier, 1966).
  2. E. Schröck, S. du Manoir, T. Veldman, B. Schoell, J. Wienberg, M. A. Ferguson-Smith, Y. Nihg, D. H. Ledbetter, I. Bar-Am, D. Soenksen, Y. Garini, and T. Ried, “Multicolor spectral karyotyping of human chromosomes,” Science 273, 494–497(1996). [CrossRef] [PubMed]
  3. N. N. Boustany, S. C. Kuo, and N. V. Thakor, “Optical scattering imaging: subcellular morphometry in situ with Fourier filtering,” Opt. Lett. 26, 1063–1065 (2001). [CrossRef]
  4. A. Wax, C. Yang, and J. A. Izatt, “Fourier-domain low coherence interferometry for light-scattering spectroscopy,” Opt. Lett. 28, 1230–1232 (2003). [CrossRef] [PubMed]
  5. A. Curry, G. Nusz, A. Chicolti, and A. Wax, “Substrate effect on refractive index dependence of plasmons resonances for individual silver nanoparticles observed using dark field microspectroscopy,” Opt. Express 13, 2668–2677 (2005). [CrossRef] [PubMed]
  6. J. Prikulis, F. Svedberg, M. Käll, J. Enger, K. Ramser, M. Goksör, and D. Hanstorp, “Optical spectroscopy of single trapped metal nanoparticles in solution,” Nano Lett. 4, 115–118 (2004). [CrossRef]
  7. Y. Liu, X. Li, Y. L. Kim, and V. Backman, “Elastic backscattering spectroscopy microscopy,” Opt. Lett. 30, 2445–2447 (2005). [CrossRef] [PubMed]
  8. M. T. Valentine, A. K. Popp, D. A. Weitz, and P. D. Kaplan, “Microscope-based static light-scattering instrument,” Opt. Lett. 26, 890–892 (2001). [CrossRef]
  9. B. J. Berne and R. Pecora, Dynamic Light Scattering with Application to Chemistry, Biology and Physics (Wiley, 1976).
  10. N. De Jaeger, H. Demeyere, R. Finsy, R. Sneyers, J. Vanderdeelen, P. Van der Meeren, and M. van Laethem, “Particle sizing by correlation spectroscopy,” Part. Part. Syst. Charact. 8, 179–186 (1991). [CrossRef]
  11. S. Suissa, C. Place, E. Goillot, and E. Freyssingeas, “Internal dynamics of a living cell nucleus investigated by dynamic light scattering,” Eur. Phys. J. E 26, 435–448 (2008). [CrossRef]
  12. T. Maeda and S. Fujime, “Quasielastic light scattering under optical microscope,” Rev. Sci. Instrum. 43, 566–567(1972). [CrossRef]
  13. T. Cochrane and J. C. Earnshaw, “Practical laser Doppler microscopes,” J. Phys. E 11, 196–198 (1978). [CrossRef]
  14. P. S. Blank, R. B. Tishler, and F. D. Carlson, “Quasielastic light scattering microscope spectrometer,” Appl. Opt. 26, 351–356(1987). [CrossRef] [PubMed]
  15. J.-C. Wang, “A novel optical microscope laser light scattering system,” Opt. Commun. 155, 236–240 (1998). [CrossRef]
  16. J.-C. Wang, “Design and testing of a novel microscopic photon correlation spectrometer with higher accuracy,” J. Opt. A: Pure Appl. Opt. 3, 360–365 (2001). [CrossRef]
  17. P. D. Kaplan, V. Trappe, and D. A. Weitz, “Light-scattering microscope,” Appl. Opt. 38, 4151–4157 (1999). [CrossRef]
  18. C. L. Kuyper, B. S. Fujimoto, Y. Zhao, P. G. Schirp, and D. T. Chiu, “Accurate sizing of nanoparticles using confocal correlation spectroscopy,” J. Phys. Chem. B 110, 24433–24441(2006). [CrossRef] [PubMed]
  19. D. S. Horne, “Particle size measurements in concentrated latex suspensions using fibre-optic photon correlation spectroscopy,” J. Phys. D 22, 1257–1265 (1989). [CrossRef]
  20. T. W. Patapoff, T. H. Tani, and M. E. M. Cromwell, “A low-volume, short-path length dynamic light scattering sample cell for highly turbid suspensions,” Anal. Biochem. 270, 338–340 (1999). [CrossRef] [PubMed]
  21. D. W. Schaefer and B. J. Berne, “Light scattering from non-Gaussian concentration fluctuations,” Phys. Rev. Lett. 28, 475–478 (1972). [CrossRef]
  22. D. W. Schaefer and P. N. Pusey, “Statistics of non-Gaussian scattered light,” Phys. Rev. Lett. 29, 843–845(1972). [CrossRef]
  23. www.cnilaser.com.
  24. www.ciprian.com.
  25. www.licel.com.
  26. M. Medebach, N. Freiberger, and O. Glatter, “Dynamic light scattering in turbid nonergodic media,” Rev. Sci. Instrum. 79, 073907 (2008). [CrossRef]
  27. R. S. Stock and W. H. Ray, “Interpretation of photon correlation spectroscopy data: a comparison of analysis methods,” J. Polym. Sci. Polym. Phys. Ed. 23, 1393–1447(1985). [CrossRef]
  28. www.philiplaven.com/mieplot.htm.
  29. H.Z.Cummins and E.R.Pike, eds., Photon Correlation and Light Beating Spectroscopy (Plenum, 1974).
  30. D. A. Ross, “Focused laser beam effects in optical particle sizing by dynamic light scattering,” Appl. Opt. 30, 4882–4888(1991). [CrossRef] [PubMed]
  31. A. T. Forrester, “On coherence properties of light waves,” Am. J. Phys. 24, 192–196 (1956). [CrossRef]
  32. S. G. Lipson, H. Lipson, and D. S. Tannhauser, Optical Physics (Cambridge U. Press, 1995).
  33. D. J. Pine, D. A. Weitz, P. M. Chaikin, and E. Herbolzheimer, “Diffusive wave spectroscopy,” Phys. Rev. Lett. 60, 1134–1137(1988). [CrossRef] [PubMed]
  34. P. N. Pusey, “Number fluctuations of interacting particles,” J. Phys. A 12, 1805–1818 (1979). [CrossRef]
  35. S. Chandrasekhar, “Stochastic problems in physics and astronomy,” Rev. Mod. Phys. 15, 1–89 (1943). [CrossRef]
  36. O. Krichevsky and G. Bonnet, “Fluorescence correlation spectroscopy: the technique and its applications,” Rep. Prog. Phys. 65, 251–298 (2002). [CrossRef]
  37. D. Magde, E. Elson, and W. W. Webb, “Thermodynamic fluctuations in a reacting system-measurement by fluorescence correlation spectroscopy,” Phys. Rev. Lett. 29, 705–708(1972). [CrossRef]
  38. T. Wilson and A. R. Carlini, “Size of the detector in confocal imaging systems,” Opt. Lett. 12, 227–229(1987). [CrossRef] [PubMed]
  39. K. Schätzel, “Noise on photon correlation data: I. autocorrelation functions,” Quantum Opt. 2, 287–305 (1990). [CrossRef]
  40. R. Rigler, J. Widengren, and Ü. Mets, in Fluorescence Spectroscopy, O.Wolfbeis, ed. (Springer, 1993).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1 Fig. 2 Fig. 3
 
Fig. 4
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited