Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Improvements to the three-color optical CCD-based pyrometer system

Not Accessible

Your library or personal account may give you access

Abstract

We put forward an improved three-color measurement scheme with a color CCD sensor using the combination of effective wavelengths and blackbody calibrations. The process of effective wavelengths realizes the separation of the emissivity function from the measurement integral equation. This improved method not only effectively avoids errors arising from the traditional process adopting the basic wavelengths, but also simplifies the complex integral calculations. For a blackbody or graybody, the measurement performance of the pyrometer was experimentally investigated from the point of the temperature sensitivity. The results show that narrowing the spectrum bandwidth with different bandpass spectral filters may improve the temperature sensitivities. The spectrum adjustment not only makes the linear emissivity more suitable in the narrower waveband, but also reduces the numerical uncertainty of the effective wavelengths. For nongray objects, the effects of the numerical uncertainty of the effective wavelengths to measurements were quantificationally evaluated at different measurement conditions (different temperatures, emissivities, and spectrums). The results indicate that the reference values of 584, 555, and 511nm or 607, 560, and 506nm of the effective wavelengths are reasonable for the present system with the modified spectral response using Filter 1 or Filter 2. The maximum calculation errors arising from the reference effective wavelengths are less than 1.6%. In this paper, the technical realization steps of the improved method are also described. The measurement experiments of a metal sample in hot environments were carried out to further verify the applicability of this improved CCD-based pyrometer. The results agreed well with the spectrometer-based results.

© 2010 Optical Society of America

Full Article  |  PDF Article
More Like This
Theoretical evaluation of measurement uncertainties of two-color pyrometry applied to optical diagnostics

Tairan Fu, Xiaofang Cheng, and Zangjian Yang
Appl. Opt. 47(32) 6112-6123 (2008)

Radiation temperature measurement method for semitransparent materials using one-channel infrared pyrometer

Tairan Fu, Jiangfan Liu, and Anzhou Zong
Appl. Opt. 53(29) 6830-6839 (2014)

High-speed digital color imaging pyrometry

John M. Densmore, Matthew M. Biss, Kevin L. McNesby, and Barrie E. Homan
Appl. Opt. 50(17) 2659-2665 (2011)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (11)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (12)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.