OSA's Digital Library

Applied Optics

Applied Optics

APPLICATIONS-CENTERED RESEARCH IN OPTICS

  • Editor: Joseph N. Mait
  • Vol. 50, Iss. 12 — Apr. 20, 2011
  • pp: 1717–1725

Instrumental phase-based method for Fourier transform spectrometer measurements processing

Bortolino Saggin, Diego Scaccabarozzi, and Marco Tarabini  »View Author Affiliations


Applied Optics, Vol. 50, Issue 12, pp. 1717-1725 (2011)
http://dx.doi.org/10.1364/AO.50.001717


View Full Text Article

Enhanced HTML    Acrobat PDF (899 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Phase correction is a critical procedure for most space-borne Fourier transform spectrometers (FTSs) whose accuracy (owing to often poor signal-to-noise ratio, SNR) can be jeopardized from many uncontrollable environmental conditions. This work considers the phase correction in an FTS working under significant temperature change during the measurement and affected by mechanical disturbances. The implemented method is based on the identification of an instrumental phase that is dependent on the interferometer temperature and on the extraction of a linear phase component through a least-squares approach. The use of an instrumental phase parameterized with the interferometer temperature eases the determination of the linear phase that can be extracted using only a narrow spectral region selected to be immune from disturbances. The procedure, in this way, is made robust against phase errors arising from instrumental effects, a key feature to reduce the disturbances through spectra averaging. The method was specifically developed for the Mars IR Mapper spectrometer, that was designed for operation onboard a rover on the Mars surface; the validation was performed using ground and in-flight measurements of the Fourier transform IR spectrometer planetary Fourier spectrometer, onboard the MarsExpress mission. The symmetrization has been exploited also for the spectra calibration, highlighting the issues deriving from the cases of relevant beamsplitter emission. The applicability of this procedure to other instruments is conditional to the presence in the spectra of at least one spectral region with a large SNR along with a negligible (or known) beamsplitter emission. For the PFS instrument, the processing of data with relevant beamsplitter emission has been performed exploiting the absorption carbon dioxide bands present in Martian spectra.

© 2011 Optical Society of America

OCIS Codes
(120.0120) Instrumentation, measurement, and metrology : Instrumentation, measurement, and metrology
(300.6340) Spectroscopy : Spectroscopy, infrared

ToC Category:
Spectroscopy

History
Original Manuscript: September 10, 2010
Revised Manuscript: December 14, 2010
Manuscript Accepted: December 14, 2010
Published: April 14, 2011

Virtual Issues
Vol. 6, Iss. 5 Virtual Journal for Biomedical Optics

Citation
Bortolino Saggin, Diego Scaccabarozzi, and Marco Tarabini, "Instrumental phase-based method for Fourier transform spectrometer measurements processing," Appl. Opt. 50, 1717-1725 (2011)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-50-12-1717


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. M. L. Forman, W. H. Steel, and G. A. Vanasse, “Correction of asymmetric interferograms obtained in Fourier spectroscopy,” J. Opt. Soc. Am. 56, 59–61 (1966). [CrossRef]
  2. L. Mertz, “Auxiliary computation for Fourier spectrometry,” Infrared Phys. 7, 17–23 (1967). [CrossRef]
  3. A. Kleinert and O. Trieschmann, “Phase determination for a Fourier transform infrared spectrometer in emission mode,” Appl. Opt. 46, 2307–2319 (2007). [CrossRef] [PubMed]
  4. C. V. Cox, P. Green, J. Pickering, J. Murray, J. E. Harries, and A. Last, “Modelling of the beamsplitter properties within the tropospheric airborne Fourier transform spectrometer (TAFTS) and associated effect on instrument calibration,” in Fourier Transform Spectroscopy, OSA Technical Digest (Optical Society of America, 2009), paper FMC4.
  5. S. Turbide and T. Smithson, “Calibration algorithm for Fourier transform spectrometer with thermal instabilities,” Appl. Opt. 49, 3411–3417 (2010). [CrossRef] [PubMed]
  6. K. Rahmelow and W. Hübner, “Phase correction in Fourier transform spectroscopy: subsequent displacement correction and error limit,” Appl. Opt. 36, 6678–6686 (1997). [CrossRef]
  7. D. B. Chase, “Phase correction in FT-IR,” Appl. Spectrosc. 36, 240–244 (1982). [CrossRef]
  8. R. C. M. Learner, A. P. Thorne, and J. W. Brault, “Ghosts and artifacts in Fourier-transform spectrometry,” Appl. Opt. 35, 2947–2954 (1996). [CrossRef] [PubMed]
  9. C. A. McCoy and J. A. de Haseth, “Modified phase correction algorithms in VCD/FT-IR spectrometry,” Mikrochim. Acta 94, 97–100 (1988). [CrossRef]
  10. T. P. Sheahen, “Chirped Fourier spectroscopy. 1: Dynamic range improvement and phase correction,” Appl. Opt. 13, 2907–2912 (1974). [CrossRef] [PubMed]
  11. H. E. Revercomb, H. Buijs, H. B. Howell, D. D. LaPorte, W. L. Smith, and L. A. Sromovsky, “Radiometric calibration of IR Fourier transform spectrometers: solution to a problem with the high-resolution interferometer sounder,” Appl. Opt. 27, 3210–3218 (1988). [CrossRef] [PubMed]
  12. S. P. Davis, Fourier Transform Spectrometry (Academic, 2001).
  13. B. Saggin, L. Comolli, and V. Formisano, “Mechanical disturbances in Fourier spectrometers,” Appl. Opt. 46, 5248–5256(2007). [CrossRef] [PubMed]
  14. B. Carli, L. Palchetti, and P. Raspollini, “Effect of beam-splitter emission in Fourier-transform emission spectroscopy,” Appl. Opt. 38, 7475–7480 (1999). [CrossRef]
  15. C. E. Blom, M. Höpfner, and C. Weddigen, “Correction of phase anomalies of atmospheric emission spectra by the double-differencing method,” Appl. Opt. 35, 2649–2652 (1996). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited