Abstract

We present an analytical model for single mode, multiply reflected, external cavity, optical fiber Fabry–Perot interferometers in the low finesse regime using simple geometry and the Gaussian beam approximation. The multiple reflection model predicts attenuation of the peak-to-peak interference as the fiber to mirror distance approaches zero, as well as fringe asymmetry in the presence of nonabsorbing mirrors. A series of experiments are conducted in which a series of fiber Fabry–Perot cavities are constructed using uncoated, single mode glass fibers, and mirrors of varying reflectivity. The cavity length is swept, and the predictions of the model are found to be in good agreement with the experimental interferograms.

© 2011 Optical Society of America

OCIS Codes
(060.2310) Fiber optics and optical communications : Fiber optics
(060.2370) Fiber optics and optical communications : Fiber optics sensors
(120.2230) Instrumentation, measurement, and metrology : Fabry-Perot
(120.3180) Instrumentation, measurement, and metrology : Interferometry

ToC Category:
Fiber Optics and Optical Communications

History
Original Manuscript: October 13, 2010
Revised Manuscript: December 16, 2010
Manuscript Accepted: July 7, 2011
Published: August 8, 2011

Citation
Paul R. Wilkinson and Jon R. Pratt, "Analytical model for low finesse, external cavity, fiber Fabry–Perot interferometers including multiple reflections and angular misalignment," Appl. Opt. 50, 4671-4680 (2011)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-50-23-4671


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. D. Rugar, H. J. Mamin, P. Guethner, “Improved fiber-optic interferometer for atomic force microscopy,” Appl. Phys. Lett. 55, 2588–2590 (1989). [CrossRef]
  2. A. Oral, R. A. Grimble, H. O. Ozer, J. B. Pethica, “High-sensitivity noncontact atomic force microscope/scanning tunneling microscope (nc-AFM/STM) operating at subangstrom oscillation amplitudes for atomic resolution imaging and force spectroscopy,” Rev. Sci. Instrum. 74, 3656–3663 (2003). [CrossRef]
  3. N. Suehira, Y. Tomiyoshi, Y. Sugawara, S. Morita, “Low-temperature noncontact atomic-force microscope with quick sample and cantilever exchange mechanism,” Rev. Sci. Instrum. 72, 2971–2976 (2001). [CrossRef]
  4. H. I. Rasool, P. R. Wilkinson, A. Z. Stieg, J. K. Gimzewski, Rev. Sci. Instrum. 81, 023703 (2010). [CrossRef] [PubMed]
  5. H. Holscher, P. Milde, U. Zerweck, L. M. Eng, R. Hoffman, “The effective quality factor at low temperature in dynamic force microscopes with Fabry–Perot interferometer detection,” Appl. Phys. Lett. 94, 223514 (2009). [CrossRef]
  6. D. T. Smith, J. R. Pratt, L. P. Howard, “A fiber-optic interferometer with subpicometer resolution for dc and low- frequency displacement measurement,” Rev. Sci. Instrum. 80, 035105 (2009). [CrossRef] [PubMed]
  7. T. D. Stowe, K. Yasumura, T. W. Kenny, D. Botkin, K. Wago, D. Rugar, “Attonewton force detection using ultrathin silicon cantilevers,” Appl. Phys. Lett. 71, 288–290 (1997). [CrossRef]
  8. S. Nemoto, T. Makimoto, “Analysis of splice loss in single-mode fibers using a Gaussian field approximation,” Opt. Quantum Electron. 11, 447–457 (1979). [CrossRef]
  9. S. Yuan, N. A. Riza, “General formula for coupling-loss characterization of single-mode fiber collimators by use of gradient-index rod lenses,” Appl. Opt. 38, 3214–3222 (1999). [CrossRef]
  10. Y. St. Amant, D. Gariepy, D. Rancourt, “Intrinsic properties of the optical coupling between axisymmetric Gaussian beams,” Appl. Opt. 43, 5691–5703 (2004). [CrossRef]
  11. V. Arya, M. De Vries, K. Murphy, A. Wang, R. O. Claus, “Exact analysis of the extrinsic Fabry–Perot interferometric optical fiber sensor using Kirchoff’s diffraction formalism,” Opt. Fiber Technol. 1, 380–384 (1995). [CrossRef]
  12. V. Arya, M. De Vries, M. Athreya, A. Wang, R. O. Claus, “Analysis of the effect of imperfect fiber endfaces on the performance of optical fiber sensors,” Opt. Eng. 35, 2262–2264 (1996). [CrossRef]
  13. M. Han, A. Wang, “Exact analysis of low-finesse multimode fiber extrinsic Fabry–Perot interferometers,” Appl. Opt. 43, 4659–4666 (2004). [CrossRef] [PubMed]
  14. K. Chin, “Interference of fiber-coupled Gaussian beam multiply reflected between two planar interfaces,” IEEE Photon. Technol. Lett. 19, 1643–1645 (2007). [CrossRef]
  15. D. Marcuse, “Loss analysis of single-mode fiber splices,” Bell Syst. Tech. J. 56, 703–719 (1977).
  16. Note that some Gaussian beam models define a spot radius in reference to the intensity of the beam, whereas others incorporate the radius of the electric field of the mode. The relation between the two is sintensity=selectric/√2.
  17. C. R. Gouy, “Sur une propiete nouvelles des ondes lumineuses,” C. R. Acad. Sci. Paris Ser. IV 110, 1251–1253 (1890).
  18. M. Han, Y. Zhang, F. Shen, G. Pickrell, A. Wang, “Signal processing algorithm for white-light optical fiber extrinsic Fabry-Perot interferometric sensors,” Opt. Lett. 29, 1736–1738 (2004). [CrossRef] [PubMed]
  19. J. R. Lawall, “Fabry–Perot metrology for displacements up to 50 mm,” J. Opt. Soc. Am. A 22, 2786–2798 (2005). [CrossRef]
  20. Commercial equipment and materials are identified in order to adequately specify certain procedures. In no case does such identification imply recommendation or endorsement by the National Institute of Technology, nor does it imply that the materials or equipment identified are necessarily the best available for the purpose.

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited