OSA's Digital Library

Applied Optics

Applied Optics

APPLICATIONS-CENTERED RESEARCH IN OPTICS

  • Editor: Joseph N. Mait
  • Vol. 51, Iss. 36 — Dec. 20, 2012
  • pp: 8606–8614

Optical analysis of a photovoltaic V-trough system installed in western India

Subarna Maiti, Nabin Sarmah, Pratap Bapat, and Tapas K. Mallick  »View Author Affiliations


Applied Optics, Vol. 51, Issue 36, pp. 8606-8614 (2012)
http://dx.doi.org/10.1364/AO.51.008606


View Full Text Article

Enhanced HTML    Acrobat PDF (1803 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

The low concentrating photovoltaic (PV) system such as a 2× V-trough system can be a promising choice for enhancing the power output from conventional PV panels with the inclusion of thermal management. This system is more attractive when the reflectors are retrofitted to the stationary PV panels installed in a high aspect ratio in the north–south direction and are tracked 12 times a year manually according to preset angles, thus eliminating the need of diurnal expensive tracking. In the present analysis, a V-trough system facing exactly the south direction is considered, where the tilt angle of the PV panels’ row is kept constant at 18.34°. The system is installed on the terrace of CSIR-Central Salt and Marine Chemicals Research Institute in Bhavnagar, Gujarat, India (21.47 N, 71.15 E). The dimension of the entire PV system is 9.64m×0.55m. The V-troughs made of anodized aluminum reflectors (70% specular reflectivity) had the same dimensions. An in-house developed; experimentally validated Monte Carlo ray-trace model was used to study the effect of the angular variation of the reflectors throughout a year for the present assembly. Results of the ray trace for the optimized angles showed the maximum simulated optical efficiency to be 85.9%. The spatial distribution of solar intensity over the 0.55 m dimension of the PV panel due to the V-trough reflectors was also studied for the optimized days in periods that included solstices and equinoxes. The measured solar intensity profiles with and without the V-trough system were used to calculate the actual optical efficiencies for several sunny days in the year, and results were validated with the simulated efficiencies within an average error limit of 10%.

© 2012 Optical Society of America

OCIS Codes
(080.2740) Geometric optics : Geometric optical design
(120.5700) Instrumentation, measurement, and metrology : Reflection
(230.4040) Optical devices : Mirrors
(350.6050) Other areas of optics : Solar energy

History
Original Manuscript: August 29, 2012
Revised Manuscript: November 14, 2012
Manuscript Accepted: November 15, 2012
Published: December 14, 2012

Citation
Subarna Maiti, Nabin Sarmah, Pratap Bapat, and Tapas K. Mallick, "Optical analysis of a photovoltaic V-trough system installed in western India," Appl. Opt. 51, 8606-8614 (2012)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-51-36-8606


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. N. Fraidenraich, “Analytic solutions for the optical properties of V-trough concentrators,” Appl. Opt. 31, 131–139 (1992). [CrossRef]
  2. R. Tang and X. Liu, “Optical performance and design optimization of V-trough concentrators for photovoltaic applications,” Sol. Energy 85, 2154–2166 (2011). [CrossRef]
  3. I. S. Taha and S. M. Eldighidy, “Effect of off-south orientation on optimum conditions for maximum solar energy absorbed by flat plate collector augmented by plane reflector,” Sol. Energy 25, 373–379 (1980). [CrossRef]
  4. H. F. Chiam, “Planar concentrators for flat plate solar collectors,” Sol. Energy 26, 503–509 (1981). [CrossRef]
  5. H. P. Garg and D. S. Hrishikesan, “Enhancement of solar energy on flat-plate collector by plane booster mirrors,” Sol. Energy 40, 295–307 (1988). [CrossRef]
  6. H. M. S. Hussein, G. E. Ahmad, and M. A. Mohamad, “Optimization of operational and design parameters of plane reflector-tilted flat plate solar collector systems,” Energy 25, 529–542 (2000). [CrossRef]
  7. M. D. J. Pucar and A. R. Despic, “The enhancement of energy gain of solar collectors and photovoltaic panels by the reflection of solar beams,” J. Energy 27, 205–223 (2002). [CrossRef]
  8. G. E. Ahmad, H. M. S. Hussein, and H. H. El-Ghetany, “Theoretical analysis and experimental verification of PV panels,” Renew. Energy 28, 1159–1168 (2003). [CrossRef]
  9. C. S. Sangani and C. S. Solanki, “Experimental evaluation of V-trough (2 suns) PV concentrator system using commercial PV panels,” Solar Energy Mater. Solar Cells 91, 453–459 (2007). [CrossRef]
  10. S. P. Sukhatme, Solar Energy: Principles of Thermal Collection and Storage, 2nd ed. (Tata McGraw-Hill, 2006).
  11. http://www.nrel.gov/midc/solpos/solpos.html .
  12. S. Maiti, S. Banerjee, K. Vyas, P. Patel, and P. K. Ghosh, “Self regulation of photovoltaic panel temperature in V-trough using a metal–wax composite phase change matrix,” Sol. Energy 85, 1805–1816 (2011). [CrossRef]
  13. T. K. Mallick, P. C. Eames, T. J. Hyde, and B. Norton, “The design and experimental characterisation of an asymmetric compound parabolic photovoltaic concentrator for building facade integration in the UK,” Sol. Energy 77, 319–327 (2004). [CrossRef]
  14. N. Sarmah, B. S. Richards, and T. K. Mallick, “Evaluation and optimization of the optical performance of low-concentrating dielectric compound parabolic concentrator using ray tracing methods,” Appl. Opt. 50, 3303–3310 (2011). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited