OSA's Digital Library

Applied Optics

Applied Optics

APPLICATIONS-CENTERED RESEARCH IN OPTICS

  • Editor: Joseph N. Mait
  • Vol. 53, Iss. 6 — Feb. 20, 2014
  • pp: 1212–1220

Influence of finite-sized detection solid angle on bidirectional reflectance distribution function measurements

Niklas Johansson, Magnus Neuman, Mattias Andersson, and Per Edström  »View Author Affiliations


Applied Optics, Vol. 53, Issue 6, pp. 1212-1220 (2014)
http://dx.doi.org/10.1364/AO.53.001212


View Full Text Article

Enhanced HTML    Acrobat PDF (633 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

This paper deals with limitations and often overlooked sources of error introduced in compact double-beam goniophotometers. It is shown that relative errors in measured radiance factor, comparable to the total measurement uncertainty, can be introduced if recommended corrections are not carried out. Two different error sources are investigated, both related to the size of the detection solid angle. The first is a geometrical error that occurs when the size of the illuminated area and detector aperture are comparable to the distance between them. The second is a convolution error due to variations in radiant flux over the detector aperture, which is quantified by simulating the full 3D bidirectional reflectance distribution function (BRDF) of a set of samples with different degrees of anisotropic reflectance. The evaluation is performed for a compact double-beam goniophotometer using different detection solid angles, and it is shown that both error sources introduce relative errors of 1%–3%, depending on viewing angle and optical properties of the sample. Commercially available compact goniophotometers, capable of absolute measurements, are becoming more and more common, and the findings in this paper are therefore important for anyone using or planning to use this type of instrument.

© 2014 Optical Society of America

OCIS Codes
(120.5700) Instrumentation, measurement, and metrology : Reflection
(120.5820) Instrumentation, measurement, and metrology : Scattering measurements
(290.5820) Scattering : Scattering measurements
(290.7050) Scattering : Turbid media
(290.1483) Scattering : BSDF, BRDF, and BTDF

ToC Category:
Scattering

History
Original Manuscript: September 25, 2013
Revised Manuscript: December 16, 2013
Manuscript Accepted: January 18, 2014
Published: February 20, 2014

Virtual Issues
Vol. 9, Iss. 4 Virtual Journal for Biomedical Optics

Citation
Niklas Johansson, Magnus Neuman, Mattias Andersson, and Per Edström, "Influence of finite-sized detection solid angle on bidirectional reflectance distribution function measurements," Appl. Opt. 53, 1212-1220 (2014)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-53-6-1212


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. M. Neuman and P. Edström, “Anisotropic reflectance from turbid media. I. Theory,” J. Opt. Soc. Am. A 27, 1032–1039 (2010). [CrossRef]
  2. M. Neuman and P. Edström, “Anisotropic reflectance from turbid media. II. Measurements,” J. Opt. Soc. Am. A 27, 1040–1045 (2010). [CrossRef]
  3. M. Neuman, L. G. Coppel, and P. Edstrom, “Angle resolved color of bulk scattering media,” Appl. Opt. 50, 6555–6563 (2011). [CrossRef]
  4. R. Drezek, A. Dunn, and R. Richards-Kortum, “Light scattering from cells: finite-difference time-domain simulations and goniometric measurements,” Appl. Opt. 38, 3651–3661 (1999). [CrossRef]
  5. Y. Zhu, Z. Ding, and M. Geiser, “Tissue scattering parameter estimation through scattering phase function measurements by goniometer,” Chin. Opt. Lett. 5, 531–533 (2007).
  6. M. Pointer, N. J. Barnes, P. J. Clarke, and M. J. Shaw, “A new goniospectrophotometer for measuring gonio-apparent materials,” Color. Technol. 121, 96–103 (2005). [CrossRef]
  7. N. Matsapey, J. Faucheu, M. Flury, and D. Delafosse, “Design of a gonio-spectro-photometer for optical characterization of gonio-apparent materials,” Meas. Sci. Technol. 24, 065901 (2013). [CrossRef]
  8. A. Ferrero, A. Rabal, J. Campos, F. Martinez-Verdu, E. Chorro, E. Perales, A. Pons, and M. Luisa Hernanz, “Spectral BRDF-based determination of proper measurement geometries to characterize color shift of special effect coatings,” J. Opt. Soc. Am. A 30, 206–214 (2013). [CrossRef]
  9. D. Hünerhoff, U. Grusemann, and A. Höpe, “New robot-based gonioreflectometer for measuring spectral diffuse reflection,” Metrologia 43, S11–S16 (2006). [CrossRef]
  10. R. Baribeau, W. S. Neil, and E. Côté, “Development of a robot-based gonioreflectometer for spectral BRDF measurements,” J. Mod. Opt. 56, 1497–1503 (2009). [CrossRef]
  11. G. Obein, R. Bousquet, and M. E. Nadal, “New NIST reference goniospectrometer,” Proc. SPIE 5880, 241–250 (2005). [CrossRef]
  12. D. Williams, “Establishment of absolute diffuse reflectance scales using the NPL reference reflectometer,” Anal. Chim. Acta 380, 165–172 (1999). [CrossRef]
  13. S. Nevas, F. Manoocheri, and E. Ikonen, “Gonioreflectometer for measuring spectral diffuse reflectance,” Appl. Opt. 43, 6391–6399 (2004). [CrossRef]
  14. F. E. Nicodemus, J. C. Richmond, J. J. Hsia, I. W. Ginsberg, and T. Limperis, Geometrical considerations and nomenclature for reflectance, (National Bureau of Standards, 1977).
  15. A. Höpe and K.-O. Hauer, “Three-dimensional appearance characterization of diffuse standard reflection materials,” Metrologia 47, 295–304 (2010). [CrossRef]
  16. M. F. Modest, Radiative Heat Transfer, 2nd ed. (Academic, 2003).
  17. P. Edström, “A fast and stable solution method for the radiative transfer problem,” SIAM Rev. 47, 447–468 (2005). [CrossRef]
  18. P. Edström, “A two-phase parameter estimation method for radiative transfer problems in paper industry applications,” Inverse Probl. Sci. Eng. 16, 927–951 (2008). [CrossRef]
  19. M. Neuman, L. G. Coppel, and P. Edström, “Point spreading in turbid media with anisotropic single scattering,” Opt. Express 19, 1915–1920 (2011). [CrossRef]
  20. P. van Nijnatten, “An automated directional reflectance/transmittance analyser for coating analysis,” Thin Solid Films 442, 74–79 (2003). [CrossRef]
  21. Joint Committee for Guides in Metrology, “Evaluation of measurement data—guide to the expression of uncertainty in measurement,” (2008).
  22. J. C. Stover, Optical Scattering, 2nd ed. (SPIE, 1995).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited