OSA's Digital Library

Applied Optics

Applied Optics

APPLICATIONS-CENTERED RESEARCH IN OPTICS

  • Vol. 9, Iss. 8 — Aug. 1, 1970
  • pp: 1926–1930

A Sensitive Spectrophotometer for Optical Reflectance and Transmittance Measurements

D. D. Sell  »View Author Affiliations


Applied Optics, Vol. 9, Issue 8, pp. 1926-1930 (1970)
http://dx.doi.org/10.1364/AO.9.001926


View Full Text Article

Enhanced HTML    Acrobat PDF (653 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A sensitive and versatile spectrophotometer for differential or absolute reflectance and transmittance measurements is described. Special sample configurations are not required, and the sample may be subjected to almost any type of external perturbation. A transparent refracting chopper is used to obtain separate sample and reference beams. A synchronous electronic circuit is used to measure the reference and sample signals while suppressing the intervening switching transients. The fractional absolute error is less than ±10−2. The peak-to-peak instrument noise is approximately 2 × 10−5 of the reference signal. Thus, changes in reflectance or transmittance as small as a few parts in 105 can be seen. In many cases this approaches the shot noise limit and is comparable to the sensitivity obtainable with modulation techniques. Examples of results for the reflectance of InP near 3.2 eV and GaAs near 1.8 eV are given.

© 1970 Optical Society of America

History
Original Manuscript: January 12, 1970
Published: August 1, 1970

Citation
D. D. Sell, "A Sensitive Spectrophotometer for Optical Reflectance and Transmittance Measurements," Appl. Opt. 9, 1926-1930 (1970)
http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-9-8-1926


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. D. Beaglehole, Appl. Opt. 7, 2218 (1968). [CrossRef] [PubMed]
  2. U. Gerhardt, G. W. Rubloff, Appl. Opt. 8, 305 (1969). [CrossRef] [PubMed]
  3. Reference 2 claims a sensitivity of ±2 × 10−5. Reference 1 claims a sensitivity of better than 10−4. A similar apparatus for transmission studies discussed by D. R. Nicol, Rev. Sci. Instrum. 40, 1300 (1969), has a sensitivity of approximately 5 × 10−3. [CrossRef]
  4. Made by Laboratory Optical Co., Plainfield, New Jersey.
  5. S. O. Rice, Bell Telephone Laboratories, Murray Hill, N. J. 07974, personal communication; and unpublished application notes obtained from Princeton Applied Research Corp., Princeton, New Jersey.
  6. K. L. Shaklee, J. E. Rowe, Appl. Opt. 9, 627 (1970). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1 Fig. 2 Fig. 3
 
Fig. 4 Fig. 5
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited