Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 40,
  • Issue 4,
  • pp. 567-571
  • (1986)

A Desolvation Unit for Introducing Microliter Volumes of a Dry Aerosol to an Atomic Spectrometric System

Not Accessible

Your library or personal account may give you access

Abstract

Recent communications from this laboratory describe an impaction-electrothermal atomization atomic absorption spectrometric (I-ETAAS) system for direct and near-real-time determination of metallic compounds in the atmosphere. Calibration was achieved by introducing aqueous standards by a pipet or by using a pneumatic nebulization aerosol deposition technique. This assumes that the transport and final atomization processes are identical for a sample introduced as an ion in solution or as a dry particle from the atmosphere. A more accurate and comparable calibration would be achieved if the standard could be introduced to the I-ETAAS system as a dry aerosol. The introduction of a dry aerosol to an atomic spectrometric system has been achieved with the use of a graphite furnace, although the major advantage of this method of sample introduction was the use of micro-volumes, minimizing sample preconcentration, and reducing interferences. The cost and availability may prevent the widespread use of the graphite furnace for sample introduction of dry aerosol. A dry aerosol has been achieved for laser-enhanced ionization spectrometry using a microcondenser with a heated injection port for introduction of sample, but only a few details of the system have been given. Browner and Boorn have recently reviewed sample introduction techniques for atomic spectrometry, pointing out that pneumatic nebulization for flames and plasmas is the preferred, most widely used, and most readily available approach in the majority of situations. Sample introduction to an electrothermal atomizer using a pneumatic nebulization aerosol deposition technique has been described. The use of pneumatic nebulization is unlikely to change in the near future despite concern over poor transport efficiency.

PDF Article
More Like This
Hot Tube Atomic Absorption Spectrochemistry

Ray Woodriff and Ronald W. Stone
Appl. Opt. 7(7) 1337-1339 (1968)

Large-volume, coolable spectroscopic cell for aerosol studies

Robert A. McPheat, David A. Newnham, R. Gary Williams, and John Ballard
Appl. Opt. 40(36) 6581-6586 (2001)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.