OSA's Digital Library

Applied Spectroscopy

Applied Spectroscopy

| PUBLISHED BY SAS — AVAILABLE FROM SAS AND OSA

  • Vol. 55, Iss. 7 — Jul. 1, 2001
  • pp: 871–876

Application of Fourier Transform Infrared Spectrometry and Chemometrics to Analysis of Polystyrene and Copolymerized Styrene in Ethylene-Styrene Copolymers

Deru Qin

Applied Spectroscopy, Vol. 55, Issue 7, pp. 871-876 (2001)


View Full Text Article

Acrobat PDF (236 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

The physical properties of ethylene-styrene (ES) copolymers, like many other copolymers, are determined primarily by copolymer composition. ES copolymers may also contain a small amount of polystyrene. It is important to quantify the copolymerized styrene and polystyrene in ES copolymers. The difficulty associated with this analysis, however, arises from the fact that copolymerized styrene and polystyrene have a similar infrared spectrum. The quantitative analysis of ethylene-styrene copolymers by the Fourier transform infrared (FT-IR) technique, combined with the partial least squares (PLS) method, is described. The use of the PLS method facilitates the analysis. The PLS factors, which are calculated iteratively to maximize the covariance between the independent variable and the dependent variable in PLS, remove the collinearity problem present in the original spectral data, and make this analysis possible. The standard error of calibration (SEC) for 60 samples included in the calibration is 0.19% for polystyrene and 0.48% for copolymerized styrene. The standard error of prediction (SEP) for polystyrene and copolymerized styrene, calculated from 120 samples that were excluded from the calibration, is 0.25 and 0.51%, respectively.

Citation
Deru Qin, "Application of Fourier Transform Infrared Spectrometry and Chemometrics to Analysis of Polystyrene and Copolymerized Styrene in Ethylene-Styrene Copolymers," Appl. Spectrosc. 55, 871-876 (2001)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-55-7-871


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited