Identification of Peaks in Capillary Column Gas Chromatograms at the Nanogram Level by Dual-Beam Fourier Transform Infrared Spectrometry

Not Accessible

Your library or personal account may give you access

Abstract

Most interfaces between a gas chromatograph (GC) and a Fourier transform infrared (FT-IR) spectrometer for the on-line measurement of the spectra of eluting peaks have been designed for use with 1/8 in. o.d. packed GC columns, and the light-pipes are too large for GC/ FT-IR measurements of peaks eluting from capillary columns without degrading the GC resolution. The volume of a light-pipe for GC/FT-IR should be large enough to ensure that as much of the sample as possible is present in the cell during the measurement of the spectrum, but small enough that the GC resolution is not seriously degraded. It has been shown that the optimum GC/FT-IR sensitivity is obtained when the volume of the light-pipe, <i>V</i><sub>cell</sub>, is equal to the volume of carrier gas containing a GC peak between its half-height points, <i>V</i><sub>1/2</sub>. For peaks eluting from lightly loaded 1/8 in. o.d. packed columns, <i>V</i><sub>1/2</sub> is usually about 5 ml or greater, while for peaks eluting from capillary columns <i>V</i><sub>1/2</sub> is considerably smaller than this. If a support-coated open tubular (SCOT) column is used, a typical value for <i>V</i><sub>1/2</sub> is 0.5 ml, and if wall-coated open tubular (WCOT) columns are used, <i>V</i><sub>1/2</sub> may be 50 μl or even lower. Thus, if GC/FT-IR techniques are to be used for the identification of components of mixtures separated by capillary columns, light-pipes of smaller volumes than the 3 ml light-pipes used on commercial GC/FT-IR systems must be used.

PDF Article
More Like This
Comparison of noise sources in dual- and single-beam Fourier-transform near-infrared spectrometry

Hans Villemoes Andersen, Anders Friderichsen, Sønnik Clausen, and Jimmy Bak
Appl. Opt. 44(29) 6167-6175 (2005)

Bilayer free-standing beam splitter for Fourier transform infrared spectrometry

N. L. Rowell and E. A. Wang
Appl. Opt. 35(16) 2927-2933 (1996)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.