Infrared Intensities of Liquids XIII: Accurate Optical Constants and Molar Absorption Coefficients Between 6500 and 435 cm-1 of Toluene at 25°C, from Spectra Recorded in Several Laboratories

Not Accessible

Your library or personal account may give you access

Abstract

This paper presents accurate infrared absorption intensities of liquid toluene at 25°C. The accuracy is estimated from the agreement between the intensities measured by different spectroscopists using the same instrument in the same laboratory and also by different spectroscopists in different laboratories using instruments made by different manufacturers. The average agreement between integrated intensities over specific wavenumber ranges is about ±1.8%. The spectra from the different laboratories have been averaged, unweighted, to give intensity spectra of toluene that are presented as the best available. The use of data from different instruments in different laboratories has included the influence of systematic instrumental errors, so that the precision of the intensity data presented should be a better approximation to its accuracy than would be the case from an extensive study by one person on one instrument. The results obtained agree with the only measurements that have been made against a primary standard, the estimated accuracy of which is about 6%. The results are presented as graphs and tables of the molar absorption coefficient spectrum and the real and imaginary refractive index spectra between 6500 and 435 cm<sup>-1</sup>. The peak heights and the areas under the bands in the imaginary refractive index (i.e., absorption index) and molar absorption coefficient spectra are reported. The absorption index, <i>k</i>(<i>v</i>), and molar absorption coefficient, <i>E</i><sub>m</sub>(<i>v</i>), values are believed to be accurate to an average ±2.5% at the peaks of 39 strong, medium, and weak bands and ±1.9% at the peaks of 51 very weak bands below 4100 cm<sup>-1</sup>. Above 4100 cm<sup>-1</sup>, 11 very weak bands have an average accuracy of ±1.3%. The baseline <i>k</i>(<i>v</i>) values are accurate to between ±3 and ±10%. The areas under bands or band groups in <i>k</i>(<i>v</i>) and ɛ<sub>m</sub>(<i>v</i>) spectra are accurate to 2.4% on average, or 1.2% for strong, medium, and weak band groups between 3150 and 775 cm<sup>-1</sup> with 0.002 < <i>k</i><sub>max</sub> < 0.112. The real refractive index, <i>n</i>(<i>v</i>), values are believed to be accurate to 0.2%.

PDF Article
More Like This
Absorption coefficients of solid NH3 from 50 to 7000 cm−1

Godfrey Sill, Uwe Fink, and John R. Ferraro
J. Opt. Soc. Am. 70(6) 724-739 (1980)

On the Infrared Absorption Spectra of Several Gases

C. F. Meyer, D. W. Bronk, and A. A. Levin
J. Opt. Soc. Am. 15(5) 257-265 (1927)

Absorption of Infrared Radiation by CO2 and H2O. II. Absorption by CO2 between 8000 and 10 000 cm−1 (1–1.25 Microns)*

Darrell E. Burch, David A. Gryvnak, and Richard R. Patty
J. Opt. Soc. Am. 58(3) 335-341 (1968)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.