OSA's Digital Library

Applied Spectroscopy

Applied Spectroscopy

| PUBLISHED BY SAS — AVAILABLE FROM SAS AND OSA

  • Vol. 48, Iss. 2 — Feb. 1, 1994
  • pp: 276–278

Diode-Laser-Based Detector for Doublet Peak Measurements in Flow Injection Analysis

Mary K. Carroll and Julian F. Tyson

Applied Spectroscopy, Vol. 48, Issue 2, pp. 276-278 (1994)


View Full Text Article

Acrobat PDF (475 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

Double peaks may be obtained in a single-line flow injection manifold if, by the time the reaction zone reaches the detector, there has been insufficient interspersion of the sample and reagent so that the sample is in excess over the reagent in the center of the reaction zone. The time between the peaks (Δt) in a doublet profile in flow injection analysis (FIA) can be related to other experimental parameters by the equation Δt = (V/Q)ln{Cs[exp(Vi/V) - 1]/CR} (1) for the "well-stirred tank" model. Variation of the volume of the mixing chamber, V, the flow rate, Q, the injected volume of sample, Vi, the concentration of sample injected, Cs, or the reagent concentration in the carrier stream, CR, affects the experimental value of Δt. The advantage of doublet peak measurements is the extension of the linear working range to higher values of concentration. If V, Q, Vi, and CR are chosen appropriately, the product profile will be a doublet with Δt proportional to ln(Cs) over a large range of analyte concentration.

Citation
Mary K. Carroll and Julian F. Tyson, "Diode-Laser-Based Detector for Doublet Peak Measurements in Flow Injection Analysis," Appl. Spectrosc. 48, 276-278 (1994)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-48-2-276

You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Log in to access OSA Member Subscription

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Log in to access OSA Member Subscription

« Previous Article

OSA is a member of CrossRef.

CrossCheck Deposited