Observations on the Measurement of Vibrational Circular Dichroism with Rapid-Scan and Step-Scan FT-IR Techniques

Not Accessible

Your library or personal account may give you access

Abstract

Extensive tests to determine an optimal method for using a Bio-Rad FTS-60A spectrometer for measurement of vibrational circular dichroism (VCD) in both step-scan and rapid-scan modes are reported. In the latter case, results of "fast-scan" and "slow-scan" experiments are also presented for comparison. In step-scan mode, phase modulation (PM) during the polarization-modulation measurements is found to be detrimental to the signal-to-noise ratio (S/N), but is very useful for the normal IR measurements at slow step speeds. VCD S/N is improved by doing sequential spectral collection of the polarization-modulated spectrum without PM and the instrument response spectra with phase modulation. Systematic comparative studies are used to identify optimal parameter sets for doing the step-scan VCD measurements. These conditions use more rapid data collection with faster steps than previously suggested, which permits a more realistic evaluation of S/N and reproducibility of the spectra through comparison of spectra collected in blocks. Example VCD spectra are presented for small molecules in nonaqueous solution measured in short times and for proteins in aqueous solution measured over longer times scales. Near-IR FT-VCD measured in step-scan mode at both moderate resolution and high S/N are presented. At this stage, fast-scan, slow-scan, and step-scan techniques are shown to be virtually equivalent in the mid-IR, but the reduction in frequency dependence of the phase correction and the new capability for VCD measurement in the near-IR favor continued development of step-scan techniques.

PDF Article
More Like This
A picosecond time-resolved vibrational circular dichroism spectrometer

Mathias Bonmarin and Jan Helbing
Opt. Lett. 33(18) 2086-2088 (2008)

Optimized interferometric setup for chiral and achiral ultrafast IR spectroscopy

Biplab Dutta and Jan Helbing
Opt. Express 23(12) 16449-16465 (2015)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.