OSA's Digital Library

Applied Spectroscopy

Applied Spectroscopy

| PUBLISHED BY SAS — AVAILABLE FROM SAS AND OSA

  • Vol. 50, Iss. 6 — Jun. 1, 1996
  • pp: 708–714

Effects of Sampling Parameters on Principal Components Analysis of Raman Line Images

Charlene A. Hayden and Michael D. Morris

Applied Spectroscopy, Vol. 50, Issue 6, pp. 708-714 (1996)


View Full Text Article

Acrobat PDF (3540 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

Raman images of the distribution of materials in a sample prepared from 10-μm-diameter polystyrene spheres embedded in epoxy were reconstructed from sets of line-scanned images, with the use of univariate and multivariate processing of the spectral data. Multiple sets of microscopic Raman spectral line images were acquired by using line-focused illumination with a cylindrical lens, a motorized translation stage to move the sample perpendicular to the illumination line, and a holographic imaging spectrograph equipped with a 2D charge-coupled device (CCD) detector. Repeat sets of data were obtained at different spectrometer slit width settings and different magnification. The raw spectral data were processed by using both a simple univariate method (single-band integration) and a more sophisticated multivariate method [principal components analysis (PCA) with eigenvector rotation] to generate 2D Raman images representing spatial distribution of the individual polymeric constituents. The repeat data sets were compared to ascertain the effects of the sampling parameters on the PCA method. The results indicated that spectrometer slit width and magnification affect the sampling depth and spatial resolution, but have little effect on the PCA. Moreover, digital sampling (i.e., number of PCA wavelength variables) could be significantly reduced with little or no degradation of the PCA-generated images, particularly if key bands were represented.

Citation
Charlene A. Hayden and Michael D. Morris, "Effects of Sampling Parameters on Principal Components Analysis of Raman Line Images," Appl. Spectrosc. 50, 708-714 (1996)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-50-6-708


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited