Measurement of Glucose in Water with First-Overtone Near-Infrared Spectra

Kevin H. Hazen, Mark A. Arnold, and Gary W. Small

Applied Spectroscopy, Vol. 52, Issue 12, pp. 1597-1605 (1998)


View Full Text Article

Acrobat PDF (307 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

Partial least-squares (PLS) regression analysis was used to build calibration models for three unique spectral data sets of glucose in water. Spectra in the first data set were collected with a 2.0 mm optical pathlength. For these data, the measured root-mean-square (rms) noise of 100% lines over the 5975-5850 cm-1 spectral range was 4.5 micro-absorbance units (mu AU). Spectrometer upgrades permitted a 5.2 mm optical pathlength for the second data set, and the resulting spectra had an rms noise of 5.9 mu AU. Further spectrometer adjustments allowed the use of a 10.0 mm optical pathlength for the third data set, and the resulting spectral rms noise was 8.4 mu AU. In each case, the instrumentation was modified individually in order to provide high radiant powers at the detector while avoiding detector saturation. Poor calibration models for the first data set indicate that a 2.0 mm optical pathlength is insufficient for adequate glucose measurements at clinically relevant concentrations. Calibration and prediction errors for the data collected at 5.2 and 10.0 mm pathlengths ranged from 0.40-0.50 and 0.35-0.40 mM, respectively. Digital Fourier filtering significantly improved model performance by reducing the required number of latent variables (factors) in the PLS models and by reducing the wavelength dependency of these models. For the best calibration model, spectra in the data set corresponding to a 10.0 mm pathlength were Fourier filtered with a Gaussian-shaped filter defined in digital frequency units (f) by a mean position of 0.0206 f and a standard deviation width of 0.0031 f. These filtered spectra were then submitted to a one-factor PLS model that is limited to the 5975-5850 cm-1 spectral range. Consideration of different spectral ranges and an analysis of spectral loading vectors indicate that the 5920 cm-1 absorption band for glucose is critical for useful analytical measurements.

Citation
Kevin H. Hazen, Mark A. Arnold, and Gary W. Small, "Measurement of Glucose in Water with First-Overtone Near-Infrared Spectra," Appl. Spectrosc. 52, 1597-1605 (1998)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-52-12-1597


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited