OSA's Digital Library

Applied Spectroscopy

Applied Spectroscopy

| PUBLISHED BY SAS — AVAILABLE FROM SAS AND OSA

  • Vol. 52, Iss. 2 — Feb. 1, 1998
  • pp: 303–307

Hybrid Photomultiplier: Its Characterization and Application as a Wide-Dynamic-Range Photon Detector

Angelo J. Alfano

Applied Spectroscopy, Vol. 52, Issue 2, pp. 303-307 (1998)


View Full Text Article

Acrobat PDF (168 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

The hybrid photomultiplier (HPMT) is commercially available in proximity- and electrostatically focused versions, and both contain a photocathode and a PIN-diode substrate. This recent addition to the family of photon detectors offers good timing characteristics, reasonable gain, excellent pulse height distribution, and a wide dynamic range. This report provides details on the wiring and characterization of a typical electrostatically focused production device for gain, impulse response, and pulse height and pulse integral linearity. A gain of 1.8 X 10 3 was obtained at less than the maximum high-voltage bias. The impulse response rise time was 1.0 ns and the fall time was 0.9 ns. The full width at half-maximum (FWHM) of the impulse response was 4.3 ns at 160 V reverse diode bias. The pulse height was linear up to 4.45 X 10 4 photoelectrons, and the pulse integral was linear up to the maximum tested (2.23 X 10 5 photoelectrons). The HPMT is not damaged by light levels that are three orders of magnitude beyond the range of linear response for a conventional PMT. Therefore, the HPMT can be directly implemented in spectroscopic applications that previously required elaborate gating schemes to protect a detector from a large optical flash that preceeds a weak subsequent optical event of interest.

Citation
Angelo J. Alfano, "Hybrid Photomultiplier: Its Characterization and Application as a Wide-Dynamic-Range Photon Detector," Appl. Spectrosc. 52, 303-307 (1998)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-52-2-303


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited