OSA's Digital Library

Applied Spectroscopy

Applied Spectroscopy

| PUBLISHED BY SAS — AVAILABLE FROM SAS AND OSA

  • Vol. 52, Iss. 3 — Mar. 1, 1998
  • pp: 462–468

Factors that Affect the Accuracy of Raman Shift Measurements on Multichannel Spectrometers

Augustus W. Fountain, Thomas J. Vickers, and Charles K. Mann

Applied Spectroscopy, Vol. 52, Issue 3, pp. 462-468 (1998)


View Full Text Article

Acrobat PDF (161 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

Raman shift measurements have been made on cyclohexane, by using linear interpolation between bracketing neon line positions to establish Raman band wavelengths. Factors that affect the precision of these measurements have been examined in detail. These include change of slit width, grating line spacing, neon line intensity, distance of separation of neon lines, and effects of small grating movements. All these have some effect, but the last factor is particularly important. Techniques that give standard deviations of 0.03 cm-1 when measurements are made without moving the grating are degraded by about an order of magnitude when the grating is moved. This result is attributed to adventitious partitioning of signal power between adjacent detector elements. By deliberately moving the grating a small amount between otherwise replicate measurements, one can control this effect. Values for the Raman shifts for eleven cyclohexane bands, based on approximately 800 Raman spectra and an equal number of neon emission spectra, are presented. The values are compared with previous measurements. They are generally within the +/- sigma range of the earlier values, but the standard deviations of these results are about an order of magnitude smaller.

Citation
Augustus W. Fountain, Thomas J. Vickers, and Charles K. Mann, "Factors that Affect the Accuracy of Raman Shift Measurements on Multichannel Spectrometers," Appl. Spectrosc. 52, 462-468 (1998)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-52-3-462


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited