Solid-Phase Extraction in Conjunction with Matrix-Assisted Laser Desorption Ionization/Quadrupole Ion Trap Mass Spectrometry for the Determination of Benzoylecgonine in Urine

Not Accessible

Your library or personal account may give you access

Abstract

A matrix-assisted laser desorption ionization/quadrupole ion trap/mass spectrometer (MALDI-QIT-MS) system is evaluated for the rapid analysis of benzoylecgonine, a cocaine metabolite, from human urine after solid-phase extraction (SPE). Collisionally activated dissociation (CAD) is utilized to provide unambiguous confirmation of benzyolecgonine. In addition, MALDI-QIT-MS is shown to be a viable, rapid quantitative method of analysis for benzoylecgonine with the inclusion of a deuterated benzoylecgonine internal standard. Linearity was established from 1 to 10 mu g/mL of benzoylecgonine in urine. A clinical urine sample known positive for benzoylecgonine was analyzed by MALDI-QIT-MS. The results indicate a mean concentration of 6.2 mu g/mL [7.4% relative standard deviation (RSD), n = 3] of benzoylecgonine by the MALDI method, which is in good agreement with the result of 7.1 mu g/mL (7.0% RSD, n = 3) obtained by a standard gas chromatography (GC)-MS procedure. Therefore, the MALDI method is demonstrated to be a rapid method for the quantitation of benzoylecgonine without post-SPE derivatization and chromatographic separation. Finally, the MALDI method is briefly extended to another class of analyte, methadone, and [( ± )-2-ethyl-1,5-dimethyl-3,3-diphenyl-pyrrolinium] (EDDP), a methadone metabolite, to demonstrate that the technique holds potential for a wide range of analytes.

PDF Article
More Like This
Resonance-ionization mass spectrometry of carbon

L. J. Moore, J. D. Fassett, J. C. Travis, T. B. Lucatorto, and C. W. Clark
J. Opt. Soc. Am. B 2(9) 1561-1565 (1985)

Resonance ionization mass spectrometry of AlxGa1−xAs: depth resolution, sensitivity, and matrix effects

S. W. Downey, R. F. Kopf, E. F. Schubert, and J. M. Kuo
Appl. Opt. 29(33) 4938-4942 (1990)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.