Optimization of Instrumentation Precision and Wavelength Resolution for the Performance of NIR Calibrations of Sucrose in a Water-Cellulose Matrix

C. V. Greensill and K. B. Walsh

Applied Spectroscopy, Vol. 54, Issue 3, pp. 426-430 (2000)


View Full Text Article

Acrobat PDF (149 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

Instrumentation for near-infrared (NIR) spectroscopic applications should be optimized for the intended application. The influence of signal precision and wavelength resolution was considered for the application of the noninvasive assessment [NIR 700-1050 nm, partial least-squares (PLS) calibration] of the sugar content of fruit, with the use of a model system of sucrose solution on cellulose. The precision (as estimated at the maximum count of the spectrum) of an MMSI Zeiss spectrometer (Carl Zeiss Pty. Ltd.) was varied by altering the number of scans averaged per spectrum, as well as the signal level. Wavelength resolution was varied between 8 and 20nm (as estimated of the 912nm Ar peak) by adjustment of the entrance slit of a prototype spectrometer employing a Hamamatsu S4874Q photodiode array as the detector, constructed on an optical bench. PLS calibrations were developed from interactance spectra of 0-20% w/v sucrose solution soaked filter papers, and compared on the basis of standard error of cross-validation (SECV) and coefficient of correlation-validation (Rv). The optimum measurement precision for calibration development was lower than expected at a coefficient of variation (CV) of 0.02 [signal-to-noise ratio (SNR) 5000:1]. Calibration performance was poorer at a resolution of < 8 nm full width at half-maximum (FWHM) in the NIR region, but not significantly different at resolutions of between 8 and 20nm. Further work is required to define the upper threshold of wavelength resolution. We conclude that instrumentation for the application of fruit sorting can have a relatively poor resolution, and can afford to operate at signal-to-noise levels considered low for a photodiode array detector. Index Headings: Coefficient of variation; NIR spectroscopy; Reflectance; Transmission; Chemometrics; Instrument design.

Citation
C. V. Greensill and K. B. Walsh, "Optimization of Instrumentation Precision and Wavelength Resolution for the Performance of NIR Calibrations of Sucrose in a Water-Cellulose Matrix," Appl. Spectrosc. 54, 426-430 (2000)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-54-3-426


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited