OSA's Digital Library

Applied Spectroscopy

Applied Spectroscopy

| PUBLISHED BY SAS — AVAILABLE FROM SAS AND OSA

  • Vol. 54, Iss. 7 — Jul. 1, 2000
  • pp: 1084–1090

Fluorescence Excitation Volume in Two-Photon Microscopy by Autocorrelation Spectroscopy and Photon Counting Histogram

Giuseppe Chirico, Francesca Olivini, and Sabrina Beretta

Applied Spectroscopy, Vol. 54, Issue 7, pp. 1084-1090 (2000)


View Full Text Article

Acrobat PDF (280 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

We compare two methods for the measurement of the excitation volume of an optical inverted microscope for two-photon excited fluorescence spectroscopy. The measure of the decay time of the fluorescence autocorrelation function gives the particles' diffusion time in the excitation volume, and from an a priori knowledge of the diffusion coefficient we can estimate the excitation volume. On the other hand, we can count the average number of particles in the excitation volume by analyzing the histogram of the fluorescence photon counting, and from the knowledge of the fluorophores' concentration we obtain the excitation volume. We show that the measurements of the excitation volume based on the analysis of the correlation function are very close, for a wide range of excitation volumes (0.1 fL < VEXC < 6 fL), to those obtained with no a priori assumptions from the analysis of the photon counting histograms. Moreover, we suggest that the study of the relation between the average number of particles in the excitation volume and the nominal concentration can be a valuable tool in verifying the good alignment of the optical setup.

Citation
Giuseppe Chirico, Francesca Olivini, and Sabrina Beretta, "Fluorescence Excitation Volume in Two-Photon Microscopy by Autocorrelation Spectroscopy and Photon Counting Histogram," Appl. Spectrosc. 54, 1084-1090 (2000)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-54-7-1084


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article

OSA is a member of CrossRef.

CrossCheck Deposited