Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 55,
  • Issue 6,
  • pp. 715-721
  • (2001)

Dual-Beam Near-Infrared Hadamard Spectrophotometer

Not Accessible

Your library or personal account may give you access

Abstract

A dual-beam Hadamard multiplexed spectrophotometer is described. The instrument is intended to work in the near-infrared region of the electromagnetic spectrum (900–1800 nm) and is based on the use of a linear Hadamard mask containing 255 multiplexing elements. Simple symmetric Czerny-Turner optics were employed based on 10 cm diameter, 20 cm focus spherical mirrors and a plane grating containing 295 grooves mm<sup>−1</sup>. The dual-path system employs the multiplexed beam exiting from the mask, which can then be split by using either an integrating sphere, a bifurcated optical bundle, or a beamsplitter. Two cooled PbS or InAs detectors were employed to collect the 255 multiplexed intensities in about 8 s. Signal was obtained by linear displacement of the mask, which was controlled by software written in VisualBasic 4.0. Spectral data were demultiplexed with a program written in the same language. The instrument can successfully correct for the drift of the light source intensity. The wavelength precision is 0.4 nm, while the average standard deviation for absorbance measurements taken from 900 to 1800 nm is 1.5 × 10<sup>−3</sup> absorbance units, a value that is about three times lower than that obtained for the single-beam multiplexed approach. The instrument has been applied to the determination of water in fuel ethanol with the use of partial least-squares modeling. The absolute standard error of prediction was 0.07% (w/w).

PDF Article
More Like This
A Beam Condenser for Infrared Spectrophotometers

Richard C. Brandt
Appl. Opt. 8(2) 315-317 (1969)

Design and testing of a new high-accuracy ultraviolet–visible–near-infrared spectrophotometer

Joanne C. Zwinkels and Denis S. Gignac
Appl. Opt. 31(10) 1557-1567 (1992)

Improved Double Beam, Vacuum Far Infrared Spectrophotometer

Isao Iwahashi, Koichi Matsumoto, Shunji Matsudaira, Shigeo Minami, and Hiroshi Yoshinaga
Appl. Opt. 8(3) 583-588 (1969)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.