Triglycerides and Glycerol Concentration Determinations Using Plasma FT-IR Spectra

Not Accessible

Your library or personal account may give you access

Abstract

FT-IR spectrometry was used for plasma triglyceride and glycerol concentration measurements, based on their most characteristic IR absorbances within the 1200-800 cm<sup>-1</sup> interval. Plasma samples from 68 sportsmen were taken at rest and after an endurance exercise that induced important lipolysis. After subtraction of glucose and lactate absorbances from exercise plasma FT-IR spectra, triglyceride concentration was accurately determined using the spectral window centered at 1106 cm<sup>-1</sup> (0.86 ± 0.19 vs. 0.84 ± 0.17 mMol/L; <i>r</i> = 0.97, <i>P</i> < 0.01; SEP = 0.14 mMol/L). Total glycerol concentration (sum of glycerol and glyceryl residue concentrations) was determined using the spectral window centered at 926 cm<sup>-1</sup>, which was found common to triglycerides and glycerol (0.306 ± 0.057 vs. 0.326 ± 0.051 mMol/L; <i>r</i> = 0.98, <i>P</i> < 0.01; SEP = 0.02 mMol/L). Glycerol concentration could be determined using the spectral window centered at 852 cm<sup>-1</sup> (0.216 ± 0.039 vs. 0.231 ± 0.048 mMol/L; <i>r</i> = 0.95, <i>P</i> < 0.01; SEP = 0.03 mMol/L). However, weak glycerol concentration could be only indirectly determined by subtracting glyceryl residue concentration from total glycerol concentration that had been determined using the spectral window centered at 926 cm<sup>-1</sup> (0.191 ± 0.061 vs. 0.176 ± 0.051 mMol/L; <i>r</i> = 0.90, <i>P</i> < 0.05; SEP = 0.02 mMol/L). Indeed, FT-IR spectrometry appears to be an accurate method for multiple biomolecular concentration determination on plasma samples.

PDF Article
More Like This
Sensing of triglyceride concentration in blood solution using photoacoustic microscopy

Nan Wan, Zhe Li, Myeongsu Seong, Ke Zhang, Wei Niu, Rong Wu, and Sung-Liang Chen
Opt. Lett. 48(14) 3769-3772 (2023)

Determination of line parameters from FTS spectra

V. Dana and A. Valentin
Appl. Opt. 27(21) 4450-4453 (1988)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.