Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 56,
  • Issue 3,
  • pp. 284-287
  • (2002)

Fourier Transform Infrared Imaging of Nematic Liquid Crystals

Not Accessible

Your library or personal account may give you access

Abstract

Fourier transform infrared spectroscopy is often used to study liquid crystals and liquid crystal systems. In this work, the factors that influence the IR absorbance of nematic liquid crystals and their consequences on FT-IR imaging are examined. In the IR spectrum of E7, ordering in the nematic phase causes a 28.7% reduction in the nitrile band height relative to the isotropic phase, and the combination of ordering and liquid crystal director alignment causes a 65.0% decrease in the nitrile band height. For a phase-separated blend of E7 and 10% NOA65 polymer, the FT-IR images were found to be concentration-based for the polymer-specific carbonyl band and phase/alignment-based, which masked the concentration dependence, for the liquid crystal-specific nitrile band. These findings were exploited to produce an FT-IR image of the isotropic-to-nematic phase transition of neat E7. This transition image emphasizes the dependence of liquid crystal bands on ordering and alignment and the need for caution in the interpretation of FT-IR images of liquid crystals and liquid crystal systems.

PDF Article
More Like This
Fourier transform spectroscopy using stressed liquid crystal

John W. McMurdy, Leslie J. Shelton, and Gregory P. Crawford
Opt. Express 17(6) 4634-4639 (2009)

Polarization-controlled contrasted images using dye-doped nematic liquid crystals

R. Porras-Aguilar, J.C. Ramirez-San-Juan, O. Baldovino-Pantaleón, D. May-Arrioja, M. L. Arroyo Carrasco, M.D. Iturbe Castillo, D. Sánchez-de-la-Llave, and R. Ramos-Garcia
Opt. Express 17(5) 3417-3423 (2009)

Laser beam propagation in nematic liquid crystals at the temperature close to the nematic-isotropic critical point

Yu-Jen Chen, Yu-Sung Lin, I-Min Jiang, and Ming-Shan Tsai
Opt. Express 16(6) 4078-4084 (2008)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.