Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 57,
  • Issue 5,
  • pp. 532-537
  • (2003)

Self-Referencing Intensity Measurements Based on SquareWave Gated Phase-Modulation Fluorimetry

Not Accessible

Your library or personal account may give you access

Abstract

An adaptation of square-wave gated phase-modulation (GPM) fluorimetry allows for self-referenced intensity measurements without the complexity of dual excitation or dual emission wavelengths. This AC technique utilizes square-wave excitation, gated detection, a reference emitter, and a sensor molecule. The theory and experimental data demonstrating the effectiveness and advantages of the adapted GPM scheme are presented. One component must have an extremely short lifetime relative to the other. Both components are affected identically by changes in intensity of the excitation source, but the sensor intensity also depends on the concentration of the analyte. The fluctuations of the excitation source and any optical transmission changes are eliminated by ratioing the sensor emission to the reference emission. As the concentration of the analyte changes, the corresponding sensor intensity changes can be quantified through several schemes including digitization of the signal and digital integration or AC methods. To measure pH, digital methods are used with Na<sub>3</sub> [Tb(dpa)<sub>3</sub>] (dpa = 2,6-pyridinedicarboxylic acid) as the long-lived reference molecule and fluorescein as the short-lived sensor molecule. Measurements from the adapted GPM scheme are directly compared to conventional ratiometric measurements. Good agreement between the data collection methods is demonstrated through the apparent pK<sub>a</sub>. For the adapted GPM measurements, conventional measurements, and a global fit the apparent pK <sub>a</sub> values agree within less than 2%. A key element of the adapted GPM method is its insensitivity to fluctuations in the source intensity. For a roughly 8-fold change in the excitation intensity, the signal ratio changes by less than 3%.

PDF Article
More Like This
Self-referenced point temperature sensor based on a fluorescence intensity ratio in Yb3+-doped silica fiber

Eric Maurice, Scott A. Wade, Stephen F. Collins, Gérard Monnom, and Greg W. Baxter
Appl. Opt. 36(31) 8264-8269 (1997)

Technique for referencing of fiber-optic intensity-modulated sensors by use of counterpropagating signals

Celia Sánchez-Pérez, Augusto García-Valenzuela, G. Eduardo Sandoval-Romero, Joel Villatoro, and Juan Hernández-Cordero
Opt. Lett. 29(13) 1467-1469 (2004)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.