Detection of Trace Water Vapor in High-Purity Phosphine Using Cavity Ring-down Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

The presence of trace water vapor in process gases such as phosphine, used for compound semiconductor epitaxial growth, can negatively affect the optical and electrical properties of the final device. Therefore, sensitive H<sub>2</sub>O measurement techniques are required to monitor precursor purity and detect unacceptable contamination levels. A commercial cavity ring-down spectrometer that monitors an H<sub>2</sub>O absorption line at a wavelength of 1392.53 nm was investigated for service in high purity PH<sub>3</sub>. Spectral parameters such as the line shape of water vapor in the presence of PH<sub>3</sub> as well as background features due to PH<sub>3</sub> were measured at different pressures and incorporated into the data analysis software for accurate moisture readings. Test concentrations generated with a diffusion vialbased H<sub>2</sub>O source and dilution manifold were used to verify instrument accuracy, sensitivity, linearity, and response time. H<sub>2</sub>O readings at 13.2 kPa corresponded well to added concentrations (slope=0.990 ± 0.01) and were linear in the tested range (0–52.7 nmol mol<sup>−1</sup>). The analyzer was sensitive to changes in H<sub>2</sub>O concentration of 1.3 nmol mol<sup>−1</sup> based on 3σ of the calibration curve intercept for a weighted linear fit. Local PH<sub>3</sub> absorption features that could not be distinguished from the H<sub>2</sub>O line were present in the purified PH<sub>3</sub> spectra and resulted in an additional systematic uncertainty of 9.0 nmol mol<sup>−1</sup>. Equilibration to changing H<sub>2</sub>O levels at a flow rate of 80 std cm<sup>3</sup> min<sup>−1</sup> PH<sub>3</sub> occurred in 10–30 minutes. The results indicate that cavity ring-down spectroscopy (CRDS) at 1392.53 nm may be useful for applications such as on-line monitoring (and dry-down) of phosphine gas delivery lines or the quality control of cylinder sources.

PDF Article
More Like This
Wavelength-modulation laser hygrometer for ultrasensitive detection of water vapor in semiconductor gases

David Christian Hovde, Joseph T. Hodges, Gregory E. Scace, and Joel A. Silver
Appl. Opt. 40(6) 829-839 (2001)

Isotope 18O/16O ratio measurements of water vapor by use of the 950-nm wavelength region with cavity ring-down and photoacoustic spectroscopic techniques

Ken Samura, Satoshi Hashimoto, Masahiro Kawasaki, Akira Hayashida, Eriko Kagi, Takashi Ishiwata, and Yutaka Matsumi
Appl. Opt. 41(12) 2349-2354 (2002)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.