A novel solid-state near-infrared spectrometer is presented based on a digital micro-mirror array device (DMD) that is well designed for Hadamard transform spectroscopy. This spectrometer is designed for the collection of transmission spectra over the C–H first overtone region of the near-infrared spectrum (6500–5500 cm−1). A spectral resolution of 2.2 nm (∼11 cm−1) is realized by using a 25 μm diameter linear tungsten filament as the source. Such a thin filament reduces imaging aberrations into the micro-mirror array, thereby enhancing spectral resolution. After passing through the sample, the transmitted radiation is dispersed with a grating before being imaged onto the surface of the DMD. Hadamard transform masks are implemented through the DMD and the reflected light is monitored by a single-element photodiode detector. The analytical utility of this approach is demonstrated through the multivariate quantification of glucose and lactate in binary mixtures composed in an aqueous buffer solution. A signal-to-noise ratio of 35 000 is achieved through these aqueous samples, and the resulting quantitative measurements provide a standard error of prediction of 1.4 and 0.9 mM for glucose and lactate, respectively. The selectivity of the resulting calibration models is established by using both a pure component selectivity analysis as well as analysis of the net analyte signal for each component. These quantitative results from the DMD Hadamard transform spectrometer compare favorably to similar measurements performed with a commercial Fourier transform spectrometer.

Virtual Issues
Vol. 6, Iss. 11 Virtual Journal for Biomedical Optics

Citation
Dong Xiang and Mark A. Arnold, "Solid-State Digital Micro-Mirror Array Spectrometer for Hadamard Transform Measurements of Glucose and Lactate in Aqueous Solutions," Appl. Spectrosc. 65, 1170-1180 (2011)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-65-10-1170


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited