Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 66,
  • Issue 10,
  • pp. 1128-1135
  • (2012)

Automated Model-Based Calibration of Short-Wavelength Infrared (SWIR) Imaging Spectrographs

Not Accessible

Your library or personal account may give you access

Abstract

Among the variety of available hyperspectral imaging systems, the line-scan technique stands out for its short acquisition time and good signal-to-noise ratio. However, due to imperfections in the camera lens and, in particular, optical components of the imaging spectrograph, the acquired images are spatially and spectrally distorted, which can significantly degrade the accuracy of the subsequent hyperspectral image analysis. In this work, we propose and evaluate an automated method for correction of spatial and spectral distortions introduced by a line-scan hyperspectral imaging system operating in the short wavelength infrared (SWIR) spectral range from 1000 nm to 2500 nm. The proposed method is based on non-rigid registration of the distorted and reference images corresponding to two passive calibration objects. The results of the validation show that the proposed method is accurate, efficient, and applicable for calibration of line-scan hyperspectral imaging systems. Moreover, the design of the method and of the calibration objects allows integration with systems operating in diffuse reflectance or transmittance modes.

PDF Article
More Like This
Characterization of a spectrograph based hyperspectral imaging system

Matjaž Kosec, Miran Bürmen, Dejan Tomaževič, Franjo Pernuš, and Boštjan Likar
Opt. Express 21(10) 12085-12099 (2013)

Deconvolution-based restoration of SWIR pushbroom imaging spectrometer images

Jurij Jemec, Franjo Pernuš, Boštjan Likar, and Miran Bürmen
Opt. Express 24(21) 24704-24718 (2016)

Observation of short wavelength infrared (SWIR) Cherenkov emission

Xu Cao, Shudong Jiang, Mengyu Jia, Jason Gunn, Tianshun Miao, Scott C. Davis, Petr Bruza, and Brian W. Pogue
Opt. Lett. 43(16) 3854-3857 (2018)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription