OSA's Digital Library

Applied Spectroscopy

Applied Spectroscopy

| PUBLISHED BY SAS — AVAILABLE FROM SAS AND OSA

  • Vol. 66, Iss. 9 — Sep. 1, 2012
  • pp: 1034–1043

Determining the Spectral Resolution of a Charge-Coupled Device (CCD) Raman Instrument

Chuan Liu and Rolf W. Berg

Applied Spectroscopy, Vol. 66, Issue 9, pp. 1034-1043 (2012)


View Full Text Article

Acrobat PDF (1517 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

A new method based on dispersion equations is described to express the spectral resolution of an applied charge-coupled device (CCD) Czerny-Turner Raman instrument entirely by means of one equation and principal factors determined by the actual setup. The factors involved are usual quantities such as wavenumber values for the laser and the Raman band, the diffraction grating groove density, the second focal length, the angle between the incident and the diffracted light, and the full width at half-maximum (FWHM) value of the signal on the detector. A basic formula is derived to estimate the spectral resolution of the Raman instrument. An essential feature of the new method is a proposed way to compensate for non-ideality (diffractions, aberrations, etc.) by use of a hyperbola model function to describe the relationship between the width of the entrance slit and the image signal width on the CCD. The model depends on the spectrometer magnification and a diffraction and aberration compensation factor denoted as A. A could be approximated as a constant that can be determined by the experimental method. The validity of the new expression has been examined by measuring the band width of the 1332.4 cm−1 diamond Raman fundamental band, excited with two quite different wavelengths (a deep ultraviolet 257.3 nm laser line and a visible green 514.5 nm line). A low pressure mercury line at 265.2042 nm also was applied to give further verification of the given expression. A useful method to find true Raman band widths is also provided. A final finding was that the known significant changes in spectral resolution along the Raman shift axis make static recording and synchronous (extended) scanning modes differ significantly with respect to their resolution properties; this feature has been often overlooked in many contemporary works reporting Raman spectra. A reason for this is that many Raman bands are too wide to show the effect.

Virtual Issues
Vol. 7, Iss. 11 Virtual Journal for Biomedical Optics

Citation
Chuan Liu and Rolf W. Berg, "Determining the Spectral Resolution of a Charge-Coupled Device (CCD) Raman Instrument," Appl. Spectrosc. 66, 1034-1043 (2012)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-66-9-1034


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited