OSA's Digital Library

Applied Spectroscopy

Applied Spectroscopy

| PUBLISHED BY SAS — AVAILABLE FROM SAS AND OSA

  • Vol. 68, Iss. 5 — May. 1, 2014
  • pp: 577–583

Instrument Response Standard in Time-Resolved Fluorescence Spectroscopy at Visible Wavelength: Quenched Fluorescein Sodium

Mengwei Liu, Menghui Jia, Haifeng Pan, Lei Li, Mengfang Chang, Hua Ren, Françoise Argoul, Sanjun Zhang, and Jianhua Xu

Applied Spectroscopy, Vol. 68, Issue 5, pp. 577-583 (2014)


View Full Text Article

Acrobat PDF (4537 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

Time-resolved fluorescence properties of quenched fluorescein sodium, including self-quenching and collisional quenching by iodide, have been studied by using a picosecond time-correlated single-photon counting (TCSPC) apparatus, together with an upconversion spectrophotofluorometer with a time resolution better than 300 fs. The steady-state fluorescence intensity of fluorescein sodium reached the maximum when its concentration was 510 μM with pH > 9. Both the fluorescence intensity and lifetime decreased with increasing concentrations of NaI quencher. When the NaI concentration was 12.2 M, a monoexponential decay with a lifetime as short as 17 ps was exactly determined for the first time using the femtosecond-resolved upconversion system. Picosecond time-resolved fluorescence measurements of circular permuted green and yellow fluorescent proteins (cpGFP and cpYFP) were reported, demonstrating that the fluorescence decay of quenched fluorescein sodium is a better approximation of the instrument response function (IRF) needed for the accurate deconvolution of fluorescence lifetime data, particularly for detectors used in the visible spectral region. We believe that this picosecond lifetime standard will find wide applications in fluorescence lifetime imaging microscopy (FLIM).

Virtual Issues
Vol. 9, Iss. 7 Virtual Journal for Biomedical Optics

Citation
Mengwei Liu, Menghui Jia, Haifeng Pan, Lei Li, Mengfang Chang, Hua Ren, Françoise Argoul, Sanjun Zhang, and Jianhua Xu, "Instrument Response Standard in Time-Resolved Fluorescence Spectroscopy at Visible Wavelength: Quenched Fluorescein Sodium," Appl. Spectrosc. 68, 577-583 (2014)
http://www.opticsinfobase.org/as/abstract.cfm?URI=as-68-5-577


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited