Abstract

Intravascular optical coherence tomography (IV-OCT) is an imaging modality that can be used for the assessment of intracoronary stents. Recent publications pointed to the fact that 3D visualizations have potential advantages compared to conventional 2D representations. However, 3D imaging still requires a time consuming manual procedure not suitable for on-line application during coronary interventions. We propose an algorithm for a rapid and fully automatic 3D visualization of IV-OCT pullbacks. IV-OCT images are first processed for the segmentation of the different structures. This also allows for automatic pullback calibration. Then, according to the segmentation results, different structures are depicted with different colors to visualize the vessel wall, the stent and the guide-wire in details. Final 3D rendering results are obtained through the use of a commercial 3D DICOM viewer. Manual analysis was used as ground-truth for the validation of the segmentation algorithms. A correlation value of 0.99 and good limits of agreement (Bland Altman statistics) were found over 250 images randomly extracted from 25 in vivo pullbacks. Moreover, 3D rendering was compared to angiography, pictures of deployed stents made available by the manufacturers and to conventional 2D imaging corroborating visualization results. Computational time for the visualization of an entire data sets resulted to be ~74 sec. The proposed method allows for the on-line use of 3D IV-OCT during percutaneous coronary interventions, potentially allowing treatments optimization.

© 2012 OSA

OCIS Codes
(100.6890) Image processing : Three-dimensional image processing
(170.4500) Medical optics and biotechnology : Optical coherence tomography
(330.5000) Vision, color, and visual optics : Vision - patterns and recognition

ToC Category:
Image Processing

History
Original Manuscript: September 14, 2012
Revised Manuscript: October 29, 2012
Manuscript Accepted: November 2, 2012
Published: November 20, 2012

Citation
Giovanni J Ughi, Tom Adriaenssens, Walter Desmet, and Jan D’hooge, "Fully automatic three-dimensional visualization of intravascular optical coherence tomography images: methods and feasibility in vivo," Biomed. Opt. Express 3, 3291-3303 (2012)
http://www.opticsinfobase.org/boe/abstract.cfm?URI=boe-3-12-3291


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. G. J. Tearney, S. Waxman, M. Shishkov, B. J. Vakoc, M. J. Suter, M. I. Freilich, A. E. Desjardins, W. Y. Oh, L. A. Bartlett, M. Rosenberg, and B. E. Bouma, “Three-dimensional coronary artery microscopy by intracoronary optical frequency domain imaging,” JACC Cardiovasc. Imaging1(6), 752–761 (2008). [CrossRef] [PubMed]
  2. E. Regar, J. A. Schaar, E. Mont, R. Virmani, and P. W. Serruys, “Optical coherence tomography,” Cardiovasc. Radiat. Med.4(4), 198–204 (2003). [CrossRef] [PubMed]
  3. T. Kume, T. Akasaka, T. Kawamoto, Y. Ogasawara, N. Watanabe, E. Toyota, Y. Neishi, R. Sukmawan, Y. Sadahira, and K. Yoshida, “Assessment of coronary arterial thrombus by optical coherence tomography,” Am. J. Cardiol.97(12), 1713–1717 (2006). [CrossRef] [PubMed]
  4. Y. Ozaki, M. Okumura, T. F. Ismail, H. Naruse, K. Hattori, S. Kan, M. Ishikawa, T. Kawai, Y. Takagi, J. Ishii, F. Prati, and P. W. Serruys, “The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study,” Eur. Heart J.31(12), 1470–1476 (2010). [CrossRef] [PubMed]
  5. V. Farooq, B. D. Gogas, T. Okamura, J. H. Heo, M. Magro, J. Gomez-Lara, Y. Onuma, M. D. Radu, S. Brugaletta, R. J. van Geuns, H. M. Garcia-Garcia, and P. W. Serruys, “Three-dimensional optical frequency domain imaging in conventional percoutaneous coronary intervention: the potential for clinical application,” Eur. Heart J. (advance access), http://eurheartj.oxfordjournals.org/content/early/2011/11/21/eurheartj.ehr409.extract .
  6. P. H. Chan, E. Alegria-Barrero, and C. Di Mario, “Tools & Techniques: Intravascular ultrasound and optical coherence tomography,” EuroIntervention7(11), 1343–1349 (2012). [CrossRef] [PubMed]
  7. T. Okamura, Y. Onuma, H. M. García-García, E. Regar, J. J. Wykrzykowska, J. Koolen, L. Thuesen, S. Windecker, R. Whitbourn, D. R. McClean, J. A. Ormiston, P. W. Serruys, and ABSORB Cohort B Investigators, “3-Dimensional optical coherence tomography assessment of jailed side branches by bioresorbable vascular scaffolds: a proposal for classification,” JACC Cardiovasc. Interv.3(8), 836–844 (2010). [CrossRef] [PubMed]
  8. T. Kubo, A. Tanaka, H. Kitabata, Y. Ino, T. Tanimoto, and T. Akasaka, “Application of optical coherence tomography in percutaneous coronary intervention,” Circ. J.76(9), 2076–2083 (2012). [CrossRef] [PubMed]
  9. B. D. Gogas, V. Farooq, Y. Onuma, M. Magro, M. D. Radu, R. J. van Geuns, E. Regar, and P. W. Serruys, “3-dimensional optical frequency domain imaging for the evaluation of primary percutaneous coronary intervention in ST-segment elevation myocardial infarction,” Int. J. Cardiol.151(1), 103–105 (2011). [CrossRef] [PubMed]
  10. T. Okamura, “Angioplasty Summit MD” (2010). http://www.summitmd.com/pdf/pdf/1430_Safety_4_TakayukiOkamura.pdf
  11. C. Di Mario, W. J. van der Giessen, N. Foin, T. Adriaenssens, P. Tyczynski, L. Ghilencea, N. Viceconte, and A. C. Linsday, “Optical coherence tomography for guidance in bifurcation lesion treatment,” EuroIntervention6(1), 99–106 (2011).
  12. H. G. Bezerra, M. A. Costa, G. Guagliumi, A. M. Rollins, and D. I. Simon, “Intracoronary optical coherence tomography: a comprehensive review clinical and research applications,” JACC Cardiovasc. Interv.2(11), 1035–1046 (2009). [CrossRef] [PubMed]
  13. L. G. Shapiro and G. C. Stockman, Computer Vision (Prentice-Hall Inc., 2001), Chaps. 3 and 10.
  14. M. Atiquzzaman and M. W. Akhtar, “A robust Hough transform technique for complete line segment description,” Real-Time Imaging1(6), 419–426 (1995). [CrossRef]
  15. Z. Wang, H. Kyono, H. G. Bezerra, D. L. Wilson, M. A. Costa, and A. M. Rollins, “Automatic segmentation of intravascular optical coherence tomography images facilitating quantitative diagnosis of atherosclerosis,” Proc. SPIE7889, 78890N, 78890N-7 (2011). [CrossRef]
  16. A. Otsu, “A threshold selection method from gray-level histograms,” IEEE Trans. Syst. Man Cybern.9(1), 62–66 (1979). [CrossRef]
  17. W. K. Pratt, Digital Image Processing (Wiley, 2001), Chap 14.
  18. T. Y. Kong and A. Rosenfeld, Topological Algorithms for Digital Image Processing (Elsevier Science, 1996), Chap 2.
  19. G. J. Ughi, T. Adriaenssens, K. Onsea, P. Kayaert, C. Dubois, P. Sinnaeve, M. Coosemans, W. Desmet, and J. D’hooge, “Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverage,” Int. J. Cardiovasc. Imaging28(2), 229–241 (2012). [CrossRef] [PubMed]
  20. G. J. Ughi, T. Adriaenssens, M. Larsson, C. Dubois, P. R. Sinnaeve, M. Coosemans, W. Desmet, and J. D’hooge, “Automatic three-dimensional registration of intravascular optical coherence tomography images,” J. Biomed. Opt.17(2), 026005 (2012). [CrossRef] [PubMed]
  21. Cybernet Systems Co, Ltd., “Free 3D DICOM viewer INTAGE Realia” (2010), http://kgt.cybernet.co.jp/viz/realia/english/intage_realia.html .
  22. J. M. Bland and D. G. Altman, “Statistical methods for assessing agreement between two methods of clinical measurement,” Lancet327(8476), 307–310 (1986). [CrossRef] [PubMed]
  23. J. Ha, H. Yoo, G. J. Tearney, and B. E. Bouma, “Compensation of motion artifacts in intracoronary optical frequency domain imaging and optical coherence tomography,” Int. J. Cardiovasc. Imaging28(6), 1299–1304 (2012). [CrossRef] [PubMed]
  24. Global Industry Analysts, Inc., “Coronary stents - a global strategic business report (2011),” http://www.strategyr.com/Coronary_Stents_Market_Report.asp .

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited